Related Experiment Video
Updated: May 5, 2026

An Aptamer-based Sensor for Unchelated GadoliniumIII
Published on: January 9, 2017
Gum kondagogu reduced/stabilized silver nanoparticles as direct colorimetric sensor for the sensitive detection of
Lori Rastogi1, R B Sashidhar, D Karunasagar
1National Centre for Compositional Characterization of Materials, Bhabha Atomic Research Centre, ECIL-Post, Hyderabad 500062, A.P., India.
Abstract:
A highly sensitive and selective method is reported for the colorimetric detection of Hg(2+) in aqueous system by using label free silver nanoparticles (Ag NPs). Ag NPs used in this method were synthesized by gum kondagogu (GK) which acted as both reducing and stabilizing agent. The average size of the GK-Ag NPs was found to be 5.0 ± 2.8 nm as revealed by transmission electron microscope (TEM) analysis and the nanoparticles were stable at various pH conditions (pH 4-11) and salt concentrations (5-100 mM). The GK reduced/stabilized Ag NPs (GK-Ag NPs) were directly used for the selective colorimetric reaction with Hg(2+) without any further modification. The bright yellow colour of Ag NPs was found to fade in a concentration dependent manner with the added Hg(+) ions. The fading response was directly correlated with increasing concentration of Hg(2+). More importantly, this response was found to be highly selective for Hg(2+) as the absorption spectra were found to be unaffected by the presence of other ions like; Na(+), K(+), Mg(2+), Ca(2+), Cu(2+), Ni(2+), Co(2+), As(3+), Fe(2+), Cd(2+), etc. The metal sensing mechanism is explained based on the turbidometric and X-ray diffraction (XRD) analysis of GK-Ag NPs with Hg(2+). The proposed method was successfully applied for the determination of Hg(2+) in various ground water samples. The reported method can be effectively used for the quantification of total Hg(2+) in samples, wherein the organic mercury is first oxidized to inorganic form by ultraviolet (UV) irradiation. The limit of quantification for Hg(2+) using the proposed method was as low as 4.9 × 10(-8) mol L(-1) (50 nM). The proposed method has potential application for on-field qualitative detection of Hg(2+) in aqueous environmental samples.
More Related Videos
09:33An Anaerobic Biosensor Assay for the Detection of Mercury and Cadmium
Published on: December 17, 2018
10:31Detection and Recovery of Palladium, Gold and Cobalt Metals from the Urban Mine Using Novel Sensors/Adsorbents Designated with Nanoscale Wagon-wheel-shaped Pores
Published on: December 6, 2015