Determining indicator toxaphene congeners in soil using comprehensive two-dimensional gas chromatography-tandem mass
Shuai Zhu1, Lirong Gao, Minghui Zheng
1State Key Laboratory of Environmental Chemistry and Ecotoxicology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, China; Agricultural University of Hebei, Baoding 071000, China.
Abstract:
Toxaphene, which is a broad spectrum chlorinated pesticide, is a complex mixture of several hundred congeners, mainly polychlorinated bornanes. Quantifying toxaphene in environmental samples is difficult because of its complexity, and because each congener has a different response factor. Toxaphene chromatograms acquired using one-dimensional gas chromatography (1DGC) show that this technique cannot be used to separate all of the toxaphene congeners. We developed and validated a sensitive and quantitative method for determining three indicator toxaphene congeners in soil using an isotope dilution/comprehensive two-dimensional gas chromatography-tandem mass spectrometry (GC × GC-MS). The samples were extracted using accelerated solvent extraction, and then the extracts were purified using silica gel columns. (13)C₁₀-labeled Parlar 26 and 50 were used as internal standards and (13)C₁₀-labeled Parlar 62 was used as an injection standard. The sample extraction and purification treatments and the GC × GC-MS parameters were optimized. Subsequently the samples were determined by GC × GC-MS. The limits of detection for Parlar 26, 50, and 62 were 0.6 pg/g, 0.4 pg/g, and 1.0 pg/g (S/N=3), respectively, and the calibration curves had good linear correlations between 50 and 1000 μg/L (r(2)>0.99). Comprehensive two-dimensional GC gave substantial improvements over one-dimensional GC in the toxaphene analysis. We analyzed soil samples containing trace quantities of toxaphene to demonstrate that the developed method could be used to analyze toxaphene in environmental samples.
More Related Videos
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Tandem Mass Spectrometry
Gas Chromatography: Types of Detectors-II
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...