Nondrainage decreases blood transfusion need and infection rate in bilateral total knee arthroplasty
Ismail Demirkale1, Osman Tecimel2, Hakan Sesen1
1Departments of Orthopaedics and Traumatology, Kecioren Education and Research Hospital, Ankara, Turkey.
Abstract:
This retrospective study enrolled 526 patients undergoing bilateral total knee arthroplasties at our institution. In nondrainage group (Group 1) of 255 patients (510 knees), a disposable elastic sterile exsanguination tourniquet (HemaClear), wound closure in layers and Jones Bandage, without pre-tourniquet removal hemostasis or Hemovac drain were used. In drainage group (Group 2) of 227 patients (454 knees), pneumatic tourniquet, post-deflation hemostasis, a Hemovac drain and Jones bandage were used. The maximal drop in hemoglobin was significantly greater in Group 2 than Group 1 (P < 0.001). Also infection rate was significantly lower in Group 1 (P = 0.017). The use of sterile tourniquet removed after wound closure without Hemovac drain decreases blood transfusion need, infection rate, tourniquet related pain and postoperative complications.