Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Electron Microscope Tomography and Single-particle Reconstruction01:07

Electron Microscope Tomography and Single-particle Reconstruction

2.1K
Transmission electron microscopy (TEM) can be used to determine the 3D structure of biological samples with the help of techniques such as electron microscope tomography and single-particle reconstruction. While single-particle reconstruction can examine macromolecules and macromolecular complexes in vitro conditions only, tomography permits the study of cell components or small cells in vivo.
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
2.1K
Cryo-electron Microscopy01:28

Cryo-electron Microscopy

3.2K
Conventional electron microscopy (EM) involves dehydration, fixation, and staining of biological samples, which distorts the native state of biological molecules and results in several artifacts. Also, the high-energy electron beam damages the sample and makes it difficult to obtain high-resolution images. These issues can be addressed using cryo-EM, which uses frozen samples and gentler electron beams. The technique was developed by Jacques Dubochet, Joachim Frank, and Richard Henderson, for...
3.2K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Molecular structure of the ESCRT-III-based archaeal CdvAB cell division machinery.

Proceedings of the National Academy of Sciences of the United States of America·2026
Same author

Foam film vitrification for cryo-EM.

Nature communications·2025
Same author

Mechanism of DNA capture by the MukBEF SMC complex and its inhibition by a viral DNA mimic.

Cell·2025
Same author

Uncovering synaptic and cellular nanoarchitecture of brain tissue via seamless <i>in situ</i> trimming and milling for cryo-electron tomography.

bioRxiv : the preprint server for biology·2025
Same author

Outcomes of the EMDataResource cryo-EM Ligand Modeling Challenge.

Nature methods·2024
Same author

Membraneless channels sieve cations in ammonia-oxidizing marine archaea.

Nature·2024

Related Experiment Video

Updated: May 5, 2026

Cryo-electron Microscopy Specimen Preparation By Means Of a Focused Ion Beam
10:54

Cryo-electron Microscopy Specimen Preparation By Means Of a Focused Ion Beam

Published on: July 26, 2014

27.1K

A cylindrical specimen holder for electron cryo-tomography.

Colin M Palmer1, Jan Löwe1

  • 1MRC Laboratory of Molecular Biology, Cambridge Biomedical Campus, Francis Crick Avenue, Cambridge CB2 0QH, UK.

Ultramicroscopy
|November 27, 2013
PubMed
Summary

Researchers developed cylindrical specimens for electron cryo-tomography, overcoming the "missing wedge" problem in frozen-hydrated samples. This technique improves tomogram quality by enabling a wider range of viewing angles.

Keywords:
Carbon nanopipettesCryoelectron tomographyCylindrical specimenElectron cryo-tomographyMissing wedgeRod-shaped specimen

More Related Videos

Cryo-Electron Tomography Remote Data Collection and Subtomogram Averaging
08:55

Cryo-Electron Tomography Remote Data Collection and Subtomogram Averaging

Published on: July 12, 2022

6.3K
Scanning Transmission Electron Microscopy Tomography in Virology: 3D Imaging of High-pressure Frozen, Freeze-substituted Samples
09:17

Scanning Transmission Electron Microscopy Tomography in Virology: 3D Imaging of High-pressure Frozen, Freeze-substituted Samples

Published on: August 6, 2025

1.1K

Related Experiment Videos

Last Updated: May 5, 2026

Cryo-electron Microscopy Specimen Preparation By Means Of a Focused Ion Beam
10:54

Cryo-electron Microscopy Specimen Preparation By Means Of a Focused Ion Beam

Published on: July 26, 2014

27.1K
Cryo-Electron Tomography Remote Data Collection and Subtomogram Averaging
08:55

Cryo-Electron Tomography Remote Data Collection and Subtomogram Averaging

Published on: July 12, 2022

6.3K
Scanning Transmission Electron Microscopy Tomography in Virology: 3D Imaging of High-pressure Frozen, Freeze-substituted Samples
09:17

Scanning Transmission Electron Microscopy Tomography in Virology: 3D Imaging of High-pressure Frozen, Freeze-substituted Samples

Published on: August 6, 2025

1.1K

Area of Science:

  • Structural Biology
  • Biophysics
  • Microscopy Techniques

Background:

  • Traditional electron cryo-tomography uses flat specimens, limiting viewing angles.
  • This limitation causes the "missing wedge" artifact, resulting in anisotropic resolution and image distortions.
  • Previous attempts at cylindrical specimens were unsuitable for frozen-hydrated samples.

Purpose of the Study:

  • To investigate the feasibility of using cylindrical specimens for frozen-hydrated samples in electron cryo-tomography.
  • To assess the impact of cylindrical specimens on mitigating the "missing wedge" problem.
  • To evaluate the quality of tomographic reconstructions from cylindrical frozen-hydrated samples.

Main Methods:

  • Developed thin-walled carbon tubes as specimen holders for creating cylindrical samples.
  • Prepared frozen-hydrated samples of ribosomes, liposomes, and bacterial cells using these holders.
  • Acquired images across a wide range of viewing angles using electron cryo-tomography.

Main Results:

  • Cylindrical frozen-hydrated samples allowed imaging from a full range of viewing angles.
  • The "missing wedge" artifact was substantially reduced in tomographic reconstructions.
  • Image quality was consistent across all viewing angles, limited only by microscope physical constraints.

Conclusions:

  • Cylindrical specimen holders effectively enable the preparation of frozen-hydrated samples for electron cryo-tomography.
  • This approach significantly reduces "missing wedge" artifacts, paving the way for improved tomogram quality.
  • Further optimization holds promise for completely eliminating artifacts and enhancing resolution in future studies.