Related Experiment Video
Updated: May 5, 2026

Identification and Protection of the Recurrent Laryngeal Nerve during Transoral Robotic Thyroidectomy
Published on: October 24, 2025
Recurrent laryngeal nerve monitoring during thoracoscopic esophagectomy
Yoshifumi Ikeda1, Taisuke Inoue, Estushi Ogawa
1Department of Surgery, Teikyo University School of Medicine, 2-11-1 Kaga, Itabashi-ku, Tokyo, 173-8605, Japan, yikeda@med.teikyo-u.ac.jp.
Introduction:
There have been several reports on the feasibility and curability of thoracoscopic esophagectomy, which may reduce injury to the thoracic cage and decrease the invasiveness of surgery. Although the recurrent laryngeal nerve (RLN) is identified and kept intact during operations, RLN palsy sometimes occurs. Currently, surgical aides, including intraoperative neurological monitoring, are being utilized to avoid RLN injury during thyroid surgery. This system is utilized during thoracoscopic esophagectomy in the prone position.
Patients And Methods:
Seven consecutive patients (six men, one woman; age range 62-74 years; mean 68 years) were included. Patients underwent general anesthesia and were intubated using the NIM TriVantage™ electromyography (EMG) tube. One-lung ventilation was performed with an endobronchial blocker. Thoracoscopic esophagectomy was performed in the prone position. The nerve stimulator was calibrated to 0.5 mA, and after the RLN was visually identified it was subsequently stimulated, which also confirmed normal machine functioning. In some situations, in the absence of a response, stimuli were increased to 1.0 mA and then 2.0 mA.
Results:
Intraoperatively, all seven patients had their nerve signals monitored. In one case, a nerve signal disappeared after complete lymph node dissection along the left RLN. This system could identify the site of injury, and the thoracoscopic magnified view allowed the disrupted point to be located precisely. When we checked VTR after surgery, the source of injury was one point tension of the nerve pulled by fiber during lymph node dissection.
Conclusions:
Intraoperative RLN monitoring during thoracoscopic esophagectomy in the prone position, with one-lung ventilation performed using the TriVantage™ EMG tube and a bronchial blocker, is technically feasible, easy, and reliable.
Related Concept Videos
Endoscopic Studies I: Bronchoscopy and Thoracoscopy
Bronchoscopy
Description
Bronchoscopy is a procedure that involves direct visualization of the larynx, trachea, and bronchi for diagnostic and therapeutic purposes. A flexible fiber optic or rigid bronchoscope is used to carry out the procedure. The fiber-optic bronchoscope is more frequently used due...
Endoscopic Studies II: Thoracocentesis
Description
Excess pleural fluid or air may accumulate in some respiratory disorders in the thoracic cavity. To treat pleural effusion, a physician conducts thoracentesis by carefully piercing the chest wall and entering...
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals....
Endotracheal Intubation II: Nursing Management
1. Nursing Care of Patients Before Intubation
Before the endotracheal intubation procedure, nurses play an essential role in ensuring the process goes smoothly. The nurses must be familiar with intubation...
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Cardiopulmonary Resuscitation V: Advanced Airway Management Techniques