Determination of the relative level of detection of a Qualitative microbiological measurement method with respect to
Irina Mărgăritescu1, Peter-Th Wilrich
1Freie Universität Berlin, Institut für Statistik und Okonometrie, Garystrasse 21, 14195 Berlin, Germany.
Abstract:
Performance of qualitative microbiological measurement methods where the results are either "O" (microorganism not detected) or "1" (microorganism detected) is described by their probability of detection (POD) function, i.e., the POD as a function of the level of contamination of the sample, expressed as CFU/g or CFU/mL, or by the level of detection (LODp), i.e., the contamination of the sample that is detected (measurement result "1") with a specified probability p. When it is impossible to obtain samples of known contamination, estimation of the POD and LOD is impossible. However, it may not be the LOD of the method that is of interest, but its LOD with respect to the LOD of a reference method. Hence, an intralaboratory experiment is performed with a reference method, R, and an alternative method, A, at different levels of unknown contamination. A complementary loglog model is used to statistically estimate the relative LOD (RLOD) of A with respect to R that is equal for all chosen values p of the POD. An intralaboratory experiment for the detection of Listeria monocytogenes in fish and eggs illustrates the method. In a simulation study, the bias of the estimate of the RLOD was investigated. This bias is due to the small number of repeated measurements in intralaboratory studies; the relative bias increases with increasing true values of the RLOD from 0 for true RLOD = 1 to about 20% for true RLOD = 3. If the number of CFUs in the test portions does not follow a Poisson distribution, but instead follows a negative binomial distribution, e.g., because of overdispersion, the bias of the estimate of the RLOD decreases. An EXCEL program RLOD_ver1. xlsm for this method of statistical analysis can be downloaded from http://www.wiwiss.fu-berlin.de/ instituteliso/mitarbeiterlwilrichlindex.html.
More Related Videos
09:15Enhanced Reproducibility and Precision of High-Throughput Quantification of Bacterial Growth Data Using a Microplate Reader
Published on: July 27, 2022
16:07Determination of the Relative Potency of an Anti-TNF Monoclonal Antibody mAb by Neutralizing TNF Using an In Vitro Bioanalytical Method
Published on: September 16, 2017
Related Concept Videos
Difference from Background: Limit of Detection
The LOD indicates the presence or absence...
Data Validation
Key parameters for method validation include:
Microbial Growth Measurement: Direct Methods
Microbial Growth Measurement: Indirect Methods
Methods to Assess Microbial Populations
Differential Leveling