Related Experiment Video
Updated: May 5, 2026

A Bedside, Single Burr Hole Approach to Multimodality Monitoring in Severe Brain Injury
Published on: March 26, 2019
Association between intra-abdominal pressure and jugular bulb saturation in critically ill patients
E Kotlinska-Hasiec1, W Dabrowski, Z Rzecki
1Department of Anesthesiology and Intensive Therapy, Medical University of Lublin, Lublin, Poland - w.dabrowski5@yahoo.com.
Background:
Disorders in cerebral circulation following elevated intra-abdominal pressure (IAP) may lead to silent brain ischemia, which can be serious problem in sedated critically ill patients. The aim of the present study was to analyse the possible association between jugular venous bulb pressure (JVBP) and jugular venous bulb saturation (SjO2) to IAP in critically ill patients.
Methods:
Adult septic shock patients with acute kidney injury were studied just after the admission to Intensive Care Unit and after 24 and 48 hours of treatment. Patients were divided into: CVVH group (patients treated with continuous veno-venous haemofiltration) and furosemide group (patients treated with furosemide infusion). The IAP was measured via the bladder. The right jugular vein was retrogradely cannulated for JVBP and SjO2 measurement. Intra-abdominal hypertension was defined as a sustained increase of IAP equal to or above 12 mmHg.
Results:
Forty patients (25 male and 15 female patients) were studied. In all participants, IAP strongly correlated with JVBP (P<0.001, r=0.73). This correlation was stronger in the furosemide group than the CVVH group. Moreover, an increase in IAP was related to an increase in JVBP and a decrease in SjO2. There was an inverse correlation between IAP and SjO2 (P<0.001, r=-0.55). This correlation was stronger in furosemide group than CVVH group.
Conclusion:
IAP is correlated to JVBP and inversely correlated to SjO2. Increase in IAP leads to elevation in JVBP and decrease in SjO2. Renal replacement therapy disturbs the correlation between IAP, JVBP and SjO2.
Related Concept Videos
Increased Intracranial Pressure l: Introduction
Measurement of Blood Pressure
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
Increased Intracranial Pressure ll: Pathophysiology
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.