Related Experiment Video
Updated: May 5, 2026

Author Spotlight: Advancing Cardiovascular Imaging - Introducing the Spatially Weighted Calcium Score for Early Disease Detection
Published on: September 22, 2023
Quantification of coronary artery plaque using 64-slice dual-source CT: comparison of semi-automatic and automatic
Young Jun Kim1, Gong Yong Jin, Eun Young Kim
1Department of Radiology, Research Institute of Clinical Medicine, Institute of Cardiovascular Research, Chonbuk National University Hospital and Medical School, 634-18 Keumam-Dong, Chonju, Jeonbuk, 561-712, South Korea.
Abstract:
We evaluated the feasibility of automatic computer-aided analysis (CAA) compared with semi-automatic CAA for differentiating lipid-rich from fibrous plaques based on coronary CT angiography (CCTA) imaging. Seventy-four coronary plaques in 57 patients were evaluated by CCTA using 64-slice dual-source CT. Quantitative analysis of coronary artery plaques was performed by measuring the relative volumes (low, medium, and calcified) of plaque components using automatic CAA and by measuring mean CT density using semi-automatic CAA. We compared the two plaque measurement methods for lipid-rich and fibrous plaques using Pearson's correlation. Intravascular ultrasonography was used as the goal standard for assessment of plaques. Mean CT density of plaques tended to increase in the order of lipid [36 ± 19 Hounsfield unit (HU)], fibrous (106 ± 34 HU), and then calcified plaques (882 ± 296 HU). The mean relative volumes of 'low' components measured by automatic CAA were 13.8 ± 4.6, 7.9 ± 6.7, and 3.5 ± 3.0 % for lipid, fibrous, and calcified plaques, respectively (r = -0.348, P = 0.022). The mean relative volumes of 'medium' components on automatic CAA were 12.9 ± 4.1, 15.7 ± 9.6, and 5.6 ± 4.8 % for lipid, fibrous, and calcified plaques, respectively (r = -0.385, P = 0.011). The mean relative volumes of low and medium components within plaques significantly correlated with the types of plaques. Plaque analysis using automatic CAA has the potential to differentiate lipid from fibrous plaques based on measurement of the relative volume percentages of the low and medium components.
More Related Videos
08:02Author Spotlight: Enhanced Quantification of Cardiovascular Calcification Progression for Longitudinal Micro PET/CT Studies in Small Research Animals
Published on: November 15, 2024
04:40Identifying Coronary Artery Calcification on Non-gated Computed Tomography Scans
Published on: August 28, 2018
Related Concept Videos
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Imaging Studies for Cardiovascular System V: CT
Acute Coronary Syndrome III: Diagnostic Studies