Related Experiment Video
Updated: May 5, 2026

Development of a Novel Internal Fixation Model for Rat Radial Fractures: Fracture Healing Assessment and Dorsal Root Ganglion Isolation
Published on: March 13, 2026
Comparison between external fixators and fixed-angle volar-locking plates in the treatment of distal radius fractures
Alberto Agustín Jorge-Mora1, David Cecilia-López, Victor Rodríguez-Vega
1Hospital 12 Octubre, Avenida de Córdoba s/n, 28041 Madrid, Spain.
Abstract:
Distal radius fractures are a common disorder in industrialized nations associated with osteoporosis, with a reported incidence of two fractures per thousand patients per year. We performed a retrospective study comparing two sets of 40 patients, with fracture of the distal radius treated with Penning external fixator, compared to 40 patients treated with fixed-angle volar-locking plate (Plate Depuy ® DVR), with the objective of finding differences between both treatment methods in anatomical values, functional outcomes and complication rates. All fractures were classified according to the AO classification. Postero-anterior and lateral radiographs of the wrist were taken after fracture, after surgery and at 6 months after surgery. We also assessed functional outcome. Minimum follow up was of 10 months. We compared complications between both groups. In the group of patients treated with fixed-angle volar-locked plate, radiological results are found to be closer to the anatomical references. Final outcomes revealed similar functional scores between both groups. The complications rate was statistically higher in the group of patients who underwent external fixation. In the fixed-angle volar-locked plate group, most of complications were related to patient discomfort due to the volar-locking plate.
More Related Videos
10:09Adjustable Stiffness, External Fixator for the Rat Femur Osteotomy and Segmental Bone Defect Models
Published on: October 9, 2014
15:11Surgical Fixation of Sternal Fractures: Preoperative Planning and a Safe Surgical Technique Using Locked Titanium Plates and Depth Limited Drilling
Published on: January 5, 2015
Related Concept Videos
Fractures: Bone Repair
Minor fractures with no bone displacement are treated by immobilizing the fractured bone using a cast or splint. However, in the case of fractures with displaced bones, the broken bones are repositioned before immobilization to ensure successful healing without deformation and loss of function. The realignment of fractured bone ends is performed through a process called reduction. If the...
Bones of the Upper Limb: Radius
The radius has a nail-shaped head, and a...
Bones of the Upper Limb: Ulna