Carbon dioxide insufflation during colorectal endoscopic submucosal dissection for patients with obstructive
Masao Yoshida1, Kenichiro Imai, Kinichi Hotta
1Division of Endoscopy, Shizuoka Cancer Center, 1007 Shimonagakubo, Nagaizumi, Sunto-gun, Shizuoka, Japan, ma.yoshida@scchr.jp.
Purpose:
Carbon dioxide (CO(2)) insufflation reduces abdominal pain and discomfort after endoscopic procedures; however, there is no previous study focusing the safety of CO(2) insufflation for patients with obstructive ventilatory disturbance. Here, we investigated the safety of CO(2) insufflation during colorectal endoscopic submucosal dissection (ESD) for patients with obstructive disturbance.
Methods:
Between January 2010 and January 2013, colorectal ESD was performed using CO(2) insufflation for 385 consecutive patients. End-tidal CO(2) (EtCO(2)) and transcutaneous oxygen saturation (SpO(2)) were consecutively measured from the time before insertion of the colonoscope to the end of ESD. Patients were monitored by two nurses during the procedure and controlled for clinical symptoms of hypercapnia such as apnea or a depressed level of consciousness. According to their respiratory function, patients were stratified into a normal group and an obstructive disturbance group. We retrospectively compared EtCO(2) and SpO(2) during the procedures and the incidence of symptoms related to CO(2) retention between the two groups.
Results:
The obstructive disturbance group consisted of 77 patients. There were similar changes of EtCO(2) in the obstructive disturbance group and normal group and no significant rise in EtCO(2). The maximum EtCO(2) level in any patient was <60 mmHg. In the obstructive disturbance group, there were no symptoms associated with CO(2) retention. There were no significant differences in the median SpO(2) between both groups and no prolonged drop of SpO(2).
Conclusions:
CO(2) insufflation during colorectal ESD is safe for patients with obstructive ventilatory disturbance.
More Related Videos
07:52Expired CO2 Measurement in Intubated or Spontaneously Breathing Patients from the Emergency Department
Published on: January 29, 2011
15:49Flexible Colonoscopy in Mice to Evaluate the Severity of Colitis and Colorectal Tumors Using a Validated Endoscopic Scoring System
Published on: October 16, 2013
Related Concept Videos
Endoscopic Procedures II: Colonoscopy
Endoscopic Procedures IV: Sigmoidoscopy and Laproscopy
Sigmoidoscopy
Sigmoidoscopy is a diagnostic procedure that uses a flexible sigmoidoscope equipped with a light source and camera to examine the rectum and sigmoid colon. The procedure involves inserting the tube through the anus...
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Endoscopic Procedures I: Esophagogastroduodenoscopy
During an EGD, the endoscope can be used to:
Endoscopic Studies II: Thoracocentesis
Description
Excess pleural fluid or air may accumulate in some respiratory disorders in the thoracic cavity. To treat pleural effusion, a physician conducts thoracentesis by carefully piercing the chest wall and entering...
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and...