Purpose Of Review:
Esophageal pressure measurement well estimates pleural pressure. The interpretation of absolute values is often debated for various reasons, but the changes in pressure measured are considered very accurate provided that a number of precautions are taken. The information provided by these measurements is unique in nature and has an enormous potential to influence management. It allows to study the exact influence of the chest wall and to determine the real lung distending pressure. It is also the only way to quantify respiratory muscle activity and the work of breathing.
Recent Findings:
The application of esophageal pressure monitoring potentially covers a large field, especially for what concerns mechanical ventilation. This goes from the acute phase of the acute respiratory distress syndrome (ARDS) to weaning and patient-ventilator interactions. During ARDS, recent findings indicate that this measurement may help titrating the level of positive end-expiratory pressure or to determine the well tolerated upper limit of airway pressure.
Summary:
Application of esophageal pressure monitoring is limited by technical issues, the need for background physiological knowledge and the fact that very few studies have assessed a direct influence of this measurement on patients' outcome. The technique is underused in everyday practice.
More Related Videos
14:09Tilt Testing with Combined Lower Body Negative Pressure: a "Gold Standard" for Measuring Orthostatic Tolerance
Published on: March 21, 2013
08:25Construction of a Wireless-Enabled Endoscopically Implantable Sensor for pH Monitoring with Zero-Bias Schottky Diode-based Receiver
Published on: August 27, 2021
Related Concept Videos
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Measurement of Blood Pressure
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of blood pressure in brachial artery(two-step method)
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure: