Related Experiment Video
Updated: May 5, 2026

Extraction and Detection of Geosmin and 2-Methylisoborneol in Water and Fish using High-Capacity Sorptive Extraction Probes and GC-MS
Published on: July 3, 2025
Highly sensitive determination of polybrominated diphenyl ethers in surface water by GC coupled to high-resolution MS
Nieves Barco-Bonilla1, Patricia Plaza-Bolaños, Noelia Ma Valera Tarifa
1Department of Chemistry and Physics (Analytical Chemistry Area), Andalusian Center for the Assessment and Monitoring of Global Change (CAESCG), Agrifood Campus of International Excellence ceiA3, University of Almería, Almería, Spain.
Abstract:
The analysis of brominated flame retardants, such as polybrominated diphenyl ethers (PBDEs), has received increased interest because of their toxicity and ubiquity. According to European Union Directive 2008/105/EC, the development of highly sensitive and selective methods capable of determining PBDEs at low concentration levels (<0.5 ng/L) is necessary. In this work, an SPE method was developed for the analysis of the six PBDEs (BDE-28, BDE-47, BDE-99, BDE-100, BDE-153, BDE-154) specified by the aforementioned directive in surface waters. The analyses were performed by GC coupled to magnetic sector high-resolution MS. The conditions were also optimized to detect the target compounds in water samples at concentrations below the environmental quality standards established by European legislation. The validated method provided adequate linearity (determination coefficient, R(2) ≥ 0.9960), recovery (101-120%, except for BDE-47 at 5 ng/L, 127%), and precision values (RSD < 20%) at two fortification levels (0.2 and 5 ng/L). The method showed LODs and LOQs ranging from 0.02 to 0.05 and from 0.05 to 0.1 ng/L, respectively. The method was applied in surface water samples, allowing the determination of these compounds at the limits established by current legislation.
More Related Videos
09:04Identifying Per- and Polyfluorinated Chemical Species with a Combined Targeted and Non-Targeted-Screening High-Resolution Mass Spectrometry Workflow
Published on: April 18, 2019
07:26A Simple Method for Automated Solid Phase Extraction of Water Samples for Immunological Analysis of Small Pollutants
Published on: January 1, 2016
Related Concept Videos
High-Performance Liquid Chromatography: Types of Detectors
Gas Chromatography: Types of Detectors-II
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....