Continuous Venous-Arterial Doppler Ultrasound During a Preload Challenge
Published on: January 20, 2023
Influence of different positions on hemodynamics derived from noninvasive transcutaneous Doppler ultrasound
Cangel Pui-Yee Chan1, Pui-Ling Cheung, Mandy Man Tse
1Accident and Emergency Medicine Academic Unit, Prince of Wales Hospital, The Chinese University of Hong Kong New Territories, Hong Kong.
Abstract:
A proper alignment of the ultrasound beam to the aortic or pulmonary outflow tracts is essential to acquire accurate signals. This study aimed to investigate the influence of different positions on the acquisition of Doppler signals using a noninvasive transcutaneous Doppler ultrasound. This was a prospective observational crossover study. Two operators performed hemodynamics measurements on each subject in supine, sitting, semirecumbent, passive leg raising (PLR) 20°, and PLR 60° positions using both aortic and pulmonary approaches. All Doppler flow profile images were assessed using the Fremantle and Prince of Wales Hospital criteria. Time required to obtain Doppler signals was recorded. A total of 60 subjects (50% males) aged 18-60 years old were investigated. In both sitting and semirecumbent positions, aortic stroke volume indexes (SVIs) and cardiac indexes (CIs) were significantly lower than those in the other three positions while the pulmonary CIs were comparable to that in the supine position. In the sitting position, the aortic signal qualities were lower and the time to obtain the pulmonary Doppler signals was prolonged. Instead, the signal quality and the time to obtain the Doppler signals in the semirecumbent position were similar to those in the other three positions using the pulmonary approach. PLR did not cause a significant increase in SVI regardless of the degree of leg elevation. These data show that it is feasible to perform the noninvasive transcutaneous Doppler ultrasound using the pulmonary approach in the semirecumbent position for patients unable to maintain the supine position. The aortic approach in the sitting and semirecumbent positions is not suitable as it is not sufficiently reliable.
More Related Videos
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.