Related Experiment Video
Updated: May 5, 2026

Point-of-Care Ultrasound for Peripheral Veno-Arterial Extracorporeal Membrane Oxygenation Without Left Ventricular Venting
Published on: January 17, 2025
Regional variation in arterial saturation and oxygen delivery during venoarterial extracorporeal membrane oxygenation
Dimitrios V Avgerinos1, William DeBois, Lilia Voevidko
1Department of Cardiothoracic Surgery and Perioperative Services, New York Presbyterian-Weill Cornell Medical Center, Weill Cornell Medical College, New York, New York 10065, USA.
Unlabelled:
Venoarterial extracorporeal membrane oxygenation (VA-ECMO) can be lifesaving in patients with cardiopulmonary collapse. However, observation studies have implied that oxygenated blood does not pass in a retrograde fashion from the VA-ECMO circuit to the aortic root and arch when the femoral artery (FA) is used. This study aims at accurately measuring the oxygen saturation in various arteries during VA-ECMO through different cannula sites. A total of 20 patients with VA-ECMO were in the study. Fourteen patients had FA cannulation, two patients received axillary arterial (AA) cannulation, and four patients received cannulation of the ascending aorta. Oxygen saturation was measured simultaneously in the radial artery and oxygenator outlet. In the patient group with FA cannulation, the oxygen saturation was lower in the radial artery (97%) when compared with the oxygenator outlet (> 99%). In the subset group of patients with severe lung dysfunction, oxygen saturation was even lower in the radial artery (73% saturation). In the patient group with AA cannulation, the oxygen saturation and partial oxygen pressure (PO2) in the oxygenator outlet and radial artery were similar (99% or greater). In the patient group with direct ascending aorta cannulation, the oxygen saturation and PO2 in the oxygenator outlet and radial artery were similar as well. Regional variations occur in the blood oxygen saturation depending on the site of the arterial cannulation in patients with VA-ECMO. With FA cannulation, the oxygen saturation in the radial artery is significantly lower than the one in the oxygenator outlet. This may imply that the coronaries and the brain receive hypoxic blood from the left ventricle. These results suggest that antegrade cannulation for VA-ECMO improves oxygen delivery to the proximal aorta distribution.
Keywords:
VA-ECMO, arterial oxygen saturation.
Related Concept Videos
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Oxygen Transport in the Blood
Respiration and Gaseous Exchange
Respiration involves the exchange of gases, especially oxygen (O2) and carbon dioxide (CO2), between the alveoli and body cells, a process facilitated by blood circulation. As a result, the cardiovascular system, which involves...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...

