Evaluation of Capnography Sampling Line Compatibility and Accuracy when Used with a Portable Capnography Monitor
Published on: September 29, 2020
Accurate and stable continuous monitoring module by mainstream capnography
Jiachen Yang1, Haitao Wang, Bin Wang
1School of Electronic Information Engineering, Tianjin University, Tianjin, People's Republic of China.
Abstract:
End-tidal partial pressure of [Formula: see text] is an important index in clinical monitoring. Medical mainstream capnography has become widely used, but there are still limitations in accuracy and stability. A type of mainstream capnometer based on the principle of non-dispersive infrared was designed. This capnometer inhibits signal drift by using electric modulation and thus ensures the accuracy of long-term CO2 monitoring. Statistical methods are used to find the best setting for sampling respiratory signals and improving precision. Several digital filtering techniques are used to process various interferences and improve capnogram quality. Clinical tests and targeted experiments show this mainstream capnometer can accurately monitor respiratory CO2 concentrations, especially at the end-tidal peak point. This capnometer also shows high accuracy and stability in long-term continuous monitoring.
More Related Videos
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Holter Monitor: 24-Hour Monitoring
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...