Abstract:
We studied 54 neonates with acute cardiorespiratory illness and 21 infants with bronchopulmonary dysplasia, to evaluate the accuracy of a nonheated pulse oximeter in predicting arterial oxygen saturation (SaO2). We also studied the accuracy of transcutaneous oxygen tension (tcPO2) in estimating arterial oxygen tension (PaO2) in infants with bronchopulmonary dysplasia. We compared pulse oximeter SaO2 with simultaneously measured SaO2 (range 78% to 100%) using a co-oximeter. Over a wide range of values for heart rate, blood pressure, hematocrit, PO2, PCO2, and pH, linear regression analysis revealed a close correlation between in vivo pulse oximeter readings and in vitro SaO2 measurements in patients with acute (r = 0.86, Y = 29.64 + 0.68X) and chronic (r = 0.91, Y = 6.29 + 0.96X) disease. Regression analysis of tcPO2 versus PaO2 showed an r value of 0.76 in infants with bronchopulmonary dysplasia. In these patients the mean difference between pulse oximeter SaO2 and in vitro SaO2 was 2.9% +/- 1.8% (SD), whereas the mean difference between tcPO2 and PaO2 was -14.5 +/- 11.1 mm Hg. Fetal hemoglobin ranged from 4.3% to 95%. We conclude that pulse oximetry is an appropriate alternative to tcPO2 for continuous oxygen monitoring in newborn infants with acute cardiorespiratory illnesses and chronic lung disease.
Related Concept Videos
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.