Revisiting a classical clinical sign: jugular venous ultrasound
Pierpaolo Pellicori1, Anna Kallvikbacka-Bennett1, Jufen Zhang1
1Department of Academic Cardiology, Hull and East Yorkshire Medical Research and Teaching Centre, MRTDS (Daisy) Building, Entrance 2, Castle Hill Hospital, Cottingham, Kingston upon Hull, HU16 5JQ, UK.
Background:
Increased jugular venous pressure, reflecting the increased right atrial pressure, is a classical sign of heart failure (HF) but clinical assessment may be difficult.
Methods:
In ambulatory patients with HF and control subjects, jugular vein diameter (JVD) was measured using a linear high-frequency ultrasound probe (10 MHz) at rest, during a Valsalva manoeuvre and during deep inspiration. JVD ratio was calculated as diameter during Valsalva to that at rest.
Results:
211 patients (mean age 70 years; mean left ventricular ejection fraction 43%) and 20 controls were included. JVD (median and inter-quartile [IQR] range) at rest was 0.17 (0.15-0.20) cm in controls and 0.23 (0.17-0.33) cm in patients with HF (p=0.012), JVD ratio was 6.3 (4.3-6.8) in controls and 4.4 (2.7-5.8) in patients with HF (p=0.001).With increasing quartiles of plasma NT-proBNP, JVD at rest rose (0.20 (0.15-0.23) cm, 0.21 (0.16-0.29) cm, 0.25 (0.18-0.35) cm and 0.34 (0.20-0.53) cm (P=<0.001), whilst JVD ratio decreased (5.4 (4.2-6.4), 4.4 (3.5-6.3), 3.9 (2.4-5.4) and 2.8 (1.7-4.7); p=<0.001). JVD ratio correlated with log (NT-proBNP) (r=-0.39, p=<0.001), LV filling pressures (E/E', r=-0.33, p=<0.001) and left atrial volume (r=-0.21, p=0.002). In a multivariable regression model, only trans-tricuspid gradient and TAPSE were independently associated with JVD ratio (R(2)=0.27).
Conclusions:
Distension of the JV at rest relative to the maximum diameter during a Valsalva manoeuvre (JVD ratio) identifies patients with heart failure who have higher plasma NT-proBNP levels, right ventricular dysfunction and raised pulmonary artery pressure.
Related Concept Videos
Venous Thrombosis II: Clinical Manifestations and Diagnostic Studies
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
Venous Return
What is Venous Return?
Venous return refers to the rate at which blood flows back to the heart from the body's peripheral veins. It's an integral part of the circulatory system...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Imaging Studies II: Ultrasonography
Ultrasonography
During an ultrasonography procedure, a handheld device called...