Related Concept Videos

Magnetic Resonance Imaging01:24

Magnetic Resonance Imaging

7.6K
Magnetic resonance imaging (MRI) is a noninvasive medical imaging technique based on a phenomenon of nuclear physics discovered in the 1930s, in which matter exposed to magnetic fields and radio waves was found to emit radio signals. In 1970, a physician and researcher named Raymond Damadian noticed that malignant (cancerous) tissue gave off different signals than normal body tissue. He applied for a patent for the first MRI scanning device in clinical use by the early 1980s. The early MRI...
7.6K
Imaging Studies IV: Magnetic Resonance Imaging01:27

Imaging Studies IV: Magnetic Resonance Imaging

427
Introduction:Magnetic Resonance Imaging, or MRI, can include a specialized imaging technique of the urinary system known as Magnetic Resonance Urography (MRU). This radiation-free technique uses strong magnetic fields and radio waves to produce detailed images with the help of a computer. MRU is particularly effective for visualizing fluid-filled structures like the kidneys, ureters, and bladder.Applications of MRI in the Genitourinary SystemKidneys and Ureters: MRI detects tumors, cysts,...
427
2D NMR: Overview of Homonuclear Correlation Techniques01:16

2D NMR: Overview of Homonuclear Correlation Techniques

803
Homonuclear correlation spectroscopy (COSY) is a powerful technique used in Nuclear Magnetic Resonance (NMR) spectroscopy to study the correlations between nuclei of the same type within a molecule. It provides information about scalar couplings between adjacent nuclei, which helps determine connectivity and structural information. There are several COSY variants, each with its unique strengths and experimental parameters.
COSY90 is the standard two-dimensional (2D) COSY experiment that...
803
NMR Spectrometers: Resolution and Error Correction01:14

NMR Spectrometers: Resolution and Error Correction

993
When magnetic nuclei in a sample achieve resonance and undergo relaxation, the signal detected in NMR is an approximately exponential free induction decay. Fourier transform of an exponential decay yields a Lorentzian peak in the frequency domain. Lorentzian peaks in an NMR spectrum are defined by their amplitude, full width at half maximum, and position, where the peak width is governed by the spin-spin relaxation time alone. In real experiments, however, the applied magnetic field is rendered...
993
Calibration Curves: Linear Least Squares01:20

Calibration Curves: Linear Least Squares

4.3K
A calibration curve is a plot of the instrument's response against a series of known concentrations of a substance. This curve is used to set the instrument response levels, using the substance and its concentrations as standards. Alternatively, or additionally, an equation is fitted to the calibration curve plot and subsequently used to calculate the unknown concentrations of other samples reliably.
For data that follow a straight line, the standard method for fitting is the linear...
4.3K
2D NMR: Overview of Heteronuclear Correlation Techniques01:18

2D NMR: Overview of Heteronuclear Correlation Techniques

905
Heteronuclear correlation spectroscopy is an analytical technique that investigates the coupling between different types of nuclei, often a proton and an X-nucleus, such as carbon-13 or nitrogen-15. This method is commonly used in nuclear magnetic resonance (NMR) spectroscopy to gain insights into complex chemical compounds' structural and compositional aspects. A typical heteronuclear correlation spectrum displays X-nucleus chemical shifts on one axis and a proton spectrum on the other...
905

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Gene dependency-informed inference of response to targeted cancer therapies.

Nature communications·2026
Same author

Dataset effects outweigh algorithmic effects in determining fairness of healthcare machine learning.

NPJ digital medicine·2026
Same author

Wearable ECG and PPG for anxiety detection: a translational digital medicine perspective.

NPJ digital medicine·2026
Same author

ECG sonification methods for robust and generalizable clinical decision support.

NPJ digital medicine·2025
Same author

Deep Probabilistic Matrix Factorization on Graphs: Application to Drug Repositioning in Antimicrobial Resistance.

IEEE transactions on computational biology and bioinformatics·2025
Same author

DREAMweb: An online tool for graph-based modeling of NMR protein structure.

Proteomics·2024

Related Experiment Video

Updated: May 5, 2026

Quantitative Magnetic Resonance Imaging of Skeletal Muscle Disease
09:30

Quantitative Magnetic Resonance Imaging of Skeletal Muscle Disease

Published on: December 18, 2016

18.6K

Calibrationless parallel magnetic resonance imaging: a joint sparsity model.

Angshul Majumdar1, Kunal Narayan Chaudhury, Rabab Ward

  • 1Department of Electrical and Computer Engineering, University of British Columbia, Vancouver, BC V6T 1Z4, Canada. angshul@iiitd.ac.in.

Sensors (Basel, Switzerland)
|December 10, 2013
PubMed
Summary

This study introduces a novel parallel MRI technique that eliminates the need for calibration scans. Our method achieves superior or comparable image reconstruction quality to existing state-of-the-art parallel MRI approaches.

More Related Videos

Quantifying Mixing using Magnetic Resonance Imaging
07:33

Quantifying Mixing using Magnetic Resonance Imaging

Published on: January 25, 2012

12.3K
Magnetic Resonance Imaging Quantification of Pulmonary Perfusion using Calibrated Arterial Spin Labeling
12:29

Magnetic Resonance Imaging Quantification of Pulmonary Perfusion using Calibrated Arterial Spin Labeling

Published on: May 30, 2011

12.7K

Related Experiment Videos

Last Updated: May 5, 2026

Quantitative Magnetic Resonance Imaging of Skeletal Muscle Disease
09:30

Quantitative Magnetic Resonance Imaging of Skeletal Muscle Disease

Published on: December 18, 2016

18.6K
Quantifying Mixing using Magnetic Resonance Imaging
07:33

Quantifying Mixing using Magnetic Resonance Imaging

Published on: January 25, 2012

12.3K
Magnetic Resonance Imaging Quantification of Pulmonary Perfusion using Calibrated Arterial Spin Labeling
12:29

Magnetic Resonance Imaging Quantification of Pulmonary Perfusion using Calibrated Arterial Spin Labeling

Published on: May 30, 2011

12.7K

Area of Science:

  • Medical Imaging
  • Magnetic Resonance Imaging (MRI)
  • Image Reconstruction

Background:

  • Current parallel MRI techniques (e.g., SENSE, GRAPPA) rely on calibration scans for parameter estimation, which can be time-consuming and prone to errors.
  • This calibration dependency makes existing methods sensitive to parameter estimation accuracy, potentially impacting reconstruction quality.

Purpose of the Study:

  • To develop a novel parallel MRI technique that bypasses the need for calibration scans.
  • To achieve high-quality image reconstruction comparable to or exceeding current state-of-the-art methods without calibration.

Main Methods:

  • Proposed a calibration-free parallel MRI method based on solving non-convex analysis and synthesis prior joint-sparsity problems.
  • Developed algorithms to solve these complex optimization problems.
  • Validated the technique on 8-channel brain and Shepp-Logan phantom datasets using Variable Density Random and non-Cartesian Radial sampling with acceleration factors of 4 and 6, respectively.

Main Results:

  • The proposed method demonstrated superior reconstruction results compared to four state-of-the-art techniques, including CS SENSE, l1SPIRiT, Distributed CS, and SAKE.
  • Quantitative evaluation using Normalized Mean Squared Error and qualitative assessment of reconstructed images confirmed the method's effectiveness.
  • Achieved high-quality reconstructions even at high acceleration factors.

Conclusions:

  • The developed calibration-free parallel MRI technique offers a significant advancement over existing methods.
  • It provides a robust and efficient alternative for accelerated MRI acquisition, potentially reducing scan times and improving patient comfort.
  • The joint-sparsity approach effectively addresses the challenges of parameter estimation in parallel MRI.