Stone-free rate (SFR): a new proposal for defining levels of SFR

Bhaskar K Somani1, Mahesh Desai, Olivier Traxer

  • 1Department of Urology, University Hospital of Southampton NHS Foundation Trust, Southampton, SO16 6YD, UK, bhaskarsomani@yahoo.com.

Urolithiasis
|December 10, 2013
PubMed

Related Concept Videos

Drug Dosing in Renal Diseases: Measurement of Glomerular Filtration Rate01:25

Drug Dosing in Renal Diseases: Measurement of Glomerular Filtration Rate

The glomerular filtration rate (GFR) is a critical indicator of kidney health, reflecting how well the kidneys filter blood. Changes in GFR can signal potential kidney impairment, necessitating accurate measurement methods to monitor kidney function effectively.Various molecules can serve as markers for GFR measurement, with the ideal marker meeting several specific criteria. It must freely filter at the glomerulus, avoid reabsorption or secretion by the renal tubules, remain unmetabolized, not...
143
Fineness Modulus01:19

Fineness Modulus

The fineness modulus (FM) of aggregate is a numerical index that measures the coarseness or fineness of the particles. It is calculated by adding the cumulative percentages of aggregate retained on each of a specified series of sieves and dividing the sum by 100.
Consider performing sieve analysis on sand through a set of ASTM sieves. The weight of aggregate retained in each sieve and pan placed at the bottom is recorded, as given in Column B of Table 1.
To determine the fineness modulus of...
2.0K
Supercritical Fluid Chromatography01:18

Supercritical Fluid Chromatography

Supercritical fluid chromatography (SFC) provides a beneficial substitute for gas chromatography (GC) and liquid chromatography (LC) for certain samples because it merges the top attributes of both techniques. SFC allows the separation and analysis of compounds that GC or LC does not easily manage. These compounds are traditionally nonvolatile or thermally unstable, making GC unsuitable and lacking functional groups required for HPLC analysis.
SFC utilizes a supercritical fluid mobile phase,...
1.5K
Identifying Statistically Significant Differences: The F-Test01:14

Identifying Statistically Significant Differences: The F-Test

The F-test is used to compare two sample variances to each other or compare the sample variance to the population variance. It is used to decide whether an indeterminate error can explain the difference in their values. The underlying assumptions that allow the use of the F-test include the data set or sets are normally distributed, and the data sets are independent of each other. The test statistic F is calculated by dividing one variance by another. In other words, the square of one standard...
3.6K
Super-resolution Fluorescence Microscopy01:37

Super-resolution Fluorescence Microscopy

Super-resolution fluorescence microscopy (SRFM) provides a better resolution than conventional fluorescence microscopy by reducing the point spread function (PSF). PSF is the light intensity distribution from a point that causes it to appear blurred. Due to PSF, each fluorescing point appears bigger than its actual size, and it is the PSF interference of nearby fluorophores that causes the blurred image. Various approaches to achieving higher resolution through SRFM have recently been...
12.3K
Fineness of Cement01:15

Fineness of Cement

The fineness of cement directly influences the rate of hydration, as the hydration begins at the surface of the cement particles. In addition to hydration, the fineness of cement is vital for various properties of concrete including workability, gypsum requirement, and long-term behavior. The fineness of cement is represented in terms of the specific surface of cement which is typically measured in square meters per kilogram, with several methods available for this determination.
Direct...
787