Related Experiment Video
Updated: May 5, 2026

Data Acquisition and Analysis In Brainstem Evoked Response Audiometry In Mice
Published on: May 10, 2019
Provisional stimulus level corrections for low frequency bone-conduction ABR in babies under three months corrected
Inga Ferm1, Guy Lightfoot, John Stevens
1* Audiology Department, Hearing Centre, Croydon University Hospital , Croydon , UK.
Objective:
To estimate bone-conduction stimulus level corrections by testing the auditory brainstem response (ABR) of normally-hearing newborns. The stimuli used were low frequency tone pips calibrated to reference levels derived from ISO 389 values.
Design:
Tone pips were presented via supra-aural earphones and a B71 Radioear bone vibrator at 0.5 or 1 kHz. ABR thresholds from both transducers were compared at each frequency.
Study Sample:
twenty-seven newborn hearing screening referrals (33 ears) who passed an ABR discharge criterion at 4 kHz.
Results:
Median air- and bone-conduction ABR threshold differences were 30 dB at 0.5 kHz and 20 dB at 1 kHz.
Conclusion:
The 0.5 kHz data from this study and previous studies were compared. Previous studies suggested lower figures for the bone-conduction stimulus level correction. Likely sources of this discrepancy are discussed. The average 0.5 kHz bone-conduction correction value for infants < 3 months old is about 28 dB. The correction for 1 kHz is 20 dB. We recommend that calibration reference levels used in this study be adopted and that appropriate corrections be applied to bone conduction ABR thresholds in infants < 3 months old before calculation of any air-bone gap and subsequent clinical interpretation.