Related Experiment Video
Updated: May 5, 2026

In Vivo Confocal Microscopy in the Diagnosis and Management of Dry Eye: A Focus on Imaging Protocols and Interpretation
Published on: November 11, 2025
Vignetting and field of view with the KAMRA corneal inlay
Achim Langenbucher1, Susanne Goebels, Nóra Szentmáry
1Experimental Ophthalmology, Saarland University, Kirrberger Strasse 100, Building 22, 66424 Homburg, Germany ; Erlangen Graduate School in Advanced Optical Technologies (SAOT), 91052 Erlangen, Germany.
Purpose:
To evaluate the effect of the KAMRA corneal inlay on the retinal image brightness in the peripheral visual field.
Methods:
A KAMRA inlay was "implanted" into a theoretical eye model in a corneal depth of 200 microns. Corneal radius was varied to a steep, normal, and flat (7.37, 7.77, and 8.17 mm) version keeping the proportion of anterior to posterior radius constant. Pupil size was varied from 2.0 to 5.0 mm. Image brightness was determined for field angles from -70° to 70° with and without KAMRA and proportion of light attenuation was recorded.
Results:
In our parameter space, the attenuation in brightness ranges in between 0 and 60%. The attenuation in brightness is not affected by corneal shape. For large field angles where the incident ray bundle is passing through the peripheral cornea, brightness is not affected. For combinations of small pupil sizes (2.0 and 2.5 mm) and field angles of 20-40°, up to 60% of light may be blocked with the KAMRA.
Conclusion:
For combinations of pupil sizes and field angles, the attenuation of image brightness reaches levels up to 60%. Our theoretical findings have to be clinically validated with detailed investigation of this vignetting effect.
More Related Videos
04:36Implantation Protocol of the Foldable Capsular Vitreous Body for Complex Vitreoretinal Surgery
Published on: April 14, 2026
04:59Author Spotlight: Enhancing Visual Outcomes in Cataract Surgery: A Novel Technique to Prevent Posterior Capsular Opacification Through IOL Rotation
Published on: July 7, 2023
Related Concept Videos
Angle Closure Glaucoma: Treatment
Focusing of Light in the Eye
Open Angle Glaucoma: Treatment
Drugs such as carbonic anhydrase inhibitors, α2- and...
Glaucoma: Overview
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Ophthalmic Drug Delivery Systems