Related Experiment Video
Updated: May 4, 2026

Video Imaging and Spatiotemporal Maps to Analyze Gastrointestinal Motility in Mice
Published on: February 3, 2016
Inference of mechanical states of intestinal motor activity using hidden Markov models
Lukasz Wiklendt, Marcello Costa, Phil G Dinning1
1Discipline of Human Physiology, Flinders Medical Science and Technology, Flinders University, Adelaide, Australia. phil.dinning@flinders.edu.au.
Background:
Contractions and relaxations of the muscle layers within the digestive tract alter the external diameter and the internal pressures. These changes in diameter and pressure move digesting food and waste products. Defining these complex relationships is a fundamental step for neurogastroenterologists to be able define normal and abnormal gut motility.
Results:
Utilising an in vitro technique that allows for the simultaneous recording of intraluminal pressure (manometry) and gut diameter (video) in an isolated section of rabbit colon, we developed a technique to help define the mechanical states of the muscle at any point in space and time during actual peristaltic movements. This was achieved by directly relating the changes in pressure to the changes in diameter along the length of the gut studied. For each individual measure of pressure or diameter, 3 dynamic state components were identified; increasing or decreasing changes or a stable period. Two additional static state components, fully contracted and fully distended, were defined for the diameter. Then qualitative mechanical states of the muscle activity were defined as combinations of these state components. A hidden Markov model was used to correlate adjacent-in-time samples, and the Viterbi algorithm was used to infer the most likely sequence of mechanical states based on the observed data. From this a spatiotemporal map of the mechanical states was produced, showing the regions of active contractions, active relaxations, or passive states along the length of the gut throughout the entire recording period.
Conclusions:
The identification of mechanical muscles states based on gut diameter and intraluminal pressure was possible by modelling muscle activation with a hidden Markov model.
Related Concept Videos
Enteric Nervous System: Regulation of GI Motor Activity
During periods of fasting, the ENS initiates the migrating myoelectric complex, a...
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and...
Gastric Motility
Peristaltic Waves and Chyme Formation
Upon food entry, the stomach initiates...