[Choice of optimal perfusion flow rate during surgical correction of combined acquired heart diseases]
Related Experiment Video
Updated: May 4, 2026

Author Spotlight: Advancing Cardiovascular Research — Tailored Langendorff Perfusion Techniques for Improved Experimental Outcomes
Published on: June 14, 2024
Abstract:
Cardiac output during the use of cardiopulmonary bypass (CPB) is defined by perfusion flow rate, which is calculated by multiplying the perfusion index (PI) on the body surface area. To date, there is no clear definition of an optimal PI and flow rate of perfusion. 60 patients operated with CPB were enrolled in the prospective study to determine the relations between different modes of perfusion and oxygen transport during surgical correction of combined valvular heart disease. Calculation of the CPB flow rate was based on PI 2.5 and 3.0 l/min/m2. Results of the study demonstrate that perfusion based on PI 2.5 l/min/m2 provides more stable oxygen transport parameters and reduces the time of ICU stay in comparison with the flow rate based on PI 3.0 l/min/m2.