Related Experiment Video

Updated: May 4, 2026

A TIRF Microscopy Technique for Real-time, Simultaneous Imaging of the TCR and its Associated Signaling Proteins
16:10

A TIRF Microscopy Technique for Real-time, Simultaneous Imaging of the TCR and its Associated Signaling Proteins

Published on: March 22, 2012

25.3K

A miniature TDCR system dedicated to in-situ activity assay

Lena Johansson1, Eleanor Bakhshandeiar1, Andy Pearce1

  • 1NPL, Middlesex, UK.

Applied Radiation and Isotopes : Including Data, Instrumentation and Methods for Use in Agriculture, Industry and Medicine
|December 18, 2013
PubMed

Abstract:

In the framework of the European Metrology Research Programme (EMRP), the Joint Research Project MetroFission has a dedicated work package for the development of a portable Triple-to-Double-Coincidence-Ratio (TDCR) system dedicated to in-situ activity measurements of low-energy beta emitters arising from the operation of the next generation of nuclear power plants. In the design phase of the NPL version of the mini-TDCR, a wide range of metrological aspects and detector types was considered. This paper summarizes these aspects of design, in the light of previous experience with the primary TDCR system at NPL. For example, in this miniature version of the TDCR, the optical chamber was simplified and cylindrical geometry was deemed sufficient. The reflectivity of the surface was increased by painted layers of Spectraflect(®), a specially formulated barium sulphate coating with high reflectivity across a wide range of wave lengths including UV. This option was chosen rather than the high performing and more expensive Spectralon(®) material used for the primary NPL TDCR. The miniature TDCR system is intended for on-site monitoring and will not require as high a performance as the primary system. Other factors that were considered included sample changing, light tightness, type of photo detector, method for varying the detection efficiency, shielding and the possible addition of an internal gamma-ray source for determination of the quench parameter of the source. In this version, the sample changing is performed using a piston and an automatic shutter. Significant design effort has been applied to ensure minimal ingress of light from the piston. Efficiency variation is accomplished by increasing the vertical displacement of the vial. Provision has been made to automate this at a later stage. Maximum light transmission to the photo-multiplier tubes is obtained at the "zero" reference height. Validation measurements were successfully performed using four different radionuclides: (3)H, (241)Pu, (63)Ni, and (99)Tc.

Keywords:
In-situ measurementLiquid scintillationPrimary standardisationTDCR

More Related Videos

Droplet Digital TRAP ddTRAP: Adaptation of the Telomere Repeat Amplification Protocol to Droplet Digital Polymerase Chain Reaction
06:38

Droplet Digital TRAP ddTRAP: Adaptation of the Telomere Repeat Amplification Protocol to Droplet Digital Polymerase Chain Reaction

Published on: May 3, 2019

8.2K
TD-DFT Guided Advanced E-Eye Sensing Technique for On-site Quantification of Fe, Cr, F, and As in the Environmental, Biological, and Food Samples
09:51

TD-DFT Guided Advanced E-Eye Sensing Technique for On-site Quantification of Fe, Cr, F, and As in the Environmental, Biological, and Food Samples

Published on: September 19, 2025

651

Related Experiment Videos

Last Updated: May 4, 2026

A TIRF Microscopy Technique for Real-time, Simultaneous Imaging of the TCR and its Associated Signaling Proteins
16:10

A TIRF Microscopy Technique for Real-time, Simultaneous Imaging of the TCR and its Associated Signaling Proteins

Published on: March 22, 2012

25.3K
Droplet Digital TRAP ddTRAP: Adaptation of the Telomere Repeat Amplification Protocol to Droplet Digital Polymerase Chain Reaction
06:38

Droplet Digital TRAP ddTRAP: Adaptation of the Telomere Repeat Amplification Protocol to Droplet Digital Polymerase Chain Reaction

Published on: May 3, 2019

8.2K
TD-DFT Guided Advanced E-Eye Sensing Technique for On-site Quantification of Fe, Cr, F, and As in the Environmental, Biological, and Food Samples
09:51

TD-DFT Guided Advanced E-Eye Sensing Technique for On-site Quantification of Fe, Cr, F, and As in the Environmental, Biological, and Food Samples

Published on: September 19, 2025

651

Related Concept Videos

Automated Microbial Diagnostics01:24

Automated Microbial Diagnostics

77
Automated diagnostic analyzers have transformed clinical microbiology by providing rapid and reliable methods for pathogen identification and antibiotic susceptibility testing. Among these systems, the Vitek 2 is widely used because it automates the traditionally labor-intensive processes of microbial identification (ID) and antibiotic susceptibility testing (AST), delivering standardized and timely results that are essential for effective patient care.Microbial Identification with ID CardsThe...
77

Articles linked to this work by shared authors, journal, and citation graph.

Radioxenon calibration, quality control, and intercomparison exercises.

Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine·2026

Statistical modeling of days alive out-of-hospital: An illustration using the SSU trial.

Journal of clinical and translational science·2026

Investigating the antimicrobial efficacy of two aerosolized hydrogen peroxide fumigation cycles for biological safety cabinet decontamination.

Journal of applied microbiology·2026

New measurements of the half-life of 225Ac at the NPL and IRA.

Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine·2026

Metformin on the Presence of COVID-19 Symptoms 6 Months after Infection: The ACTIV-6 Randomized Clinical Trial.

Clinical infectious diseases : an official publication of the Infectious Diseases Society of America·2026

Utility of point-of-care platelet aggregation testing for transfusion prediction.

Scientific reports·2026

Thermoluminescent properties and kinetics parameters of MgO:Sm,Tb+PTFE dosimeters.

Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine·2026

Methods for improving the vertical resolution of natural gamma ray logs.

Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine·2026

Occupational exposure assessment in ROLL procedures with Tc-99m: A Monte Carlo simulation approach.

Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine·2026

Dosimetric impact of prostate edema in 125I LDR brachytherapy using MCNP simulations and an adapted ICRP 110 voxel phantom.

Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine·2026

Development and application of nuclear forensic analytical capabilities at the Institute of Nuclear Chemistry and Technology.

Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine·2026

Urban radiological risk assessment using HotSpot and Geant4: From probabilistic dose estimates to shielding effects.

Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine·2026

Radiological Assessment of Atypical Femoral Fractures: A 10-Year Experience Across Two Centres.

Journal of osteoporosis·2026

Log file-based patient-specific quality assurance for MR-guided radiation therapy with comprehensive motion management.

Journal of applied clinical medical physics·2026

Reproducibility and positioning sensitivity of CT beam width measurements using a pencil ionization chamber and radiopaque mask.

Journal of applied clinical medical physics·2026

Quantitative stability of CT numbers in novel cone-beam CT: An intra-institution cross-scanner and longitudinal analysis.

Journal of applied clinical medical physics·2026

An end-to-end quality assurance procedure for pelvic VMAT using optically stimulated luminescence dosimeters and an anthropomorphic phantom.

Physical and engineering sciences in medicine·2026

End-to-end technical validation of multi-isocenter total body irradiation using an anthropomorphic phantom.

Radiological physics and technology·2026
See all related articles
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies
Jove
Visualize
Contact Us