Design and Use of a Full Flow Sampling System FFS for the Quantification of Methane Emissions
Published on: June 12, 2016
Calibration of a fugitive emission rate measurement of an area source
Colin L Y Wong1, Jeffrey Ramkellawan2
1Golder Associates Ltd., Burnaby, British Columbia, Canada. cwong@golder.com
Abstract:
A major challenge to measuring fugitive emission rates from large area sources, such as landfills or tailings ponds, has been the establishment of the accuracy of such methods, or of a particular measurement. When such measurements are carried out, they are invariably associated with a relatively high degree of uncertainty. The Airborne Matter Mapping (AMM) method is a new method of measuring fugitive emission rates that can be applied to large area sources. The method was applied to the measurement of methane emissions from a landfill to assess the potential accuracy of the method, and the measurement process was calibrated to increase confidence in the measured value. First, a measured rate of methane from a gas cylinder was released from near the center of the landfill and the AMM method was applied to measure the methane flow rate across a measurement surface. Then, the AMM method was performed a second time along the same measurement surface without the intentional release of methane. The difference of the flow rates across the measurement surface were then compared with the measured rate of methane released from the gas cylinder. The relatively small difference of -5.7% between the flow rates, relative to the methane release rate from the gas cylinder provides confidence in the accuracy of this AMM method measurement. An adjustment to the AMM method analysis was made such that the difference between the flow rates was negligible, which resulted in a calibrated measurement of the methane emission rate from the landfill of 0.87 g/sec.
More Related Videos
10:29Calibrated Passive Sampling - Multi-plot Field Measurements of NH3 Emissions with a Combination of Dynamic Tube Method and Passive Samplers
Published on: March 21, 2016
08:59Measuring Sub-23 Nanometer Real Driving Particle Number Emissions Using the Portable DownToTen Sampling System
Published on: May 22, 2020
Related Concept Videos
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Constant Volume Calorimetry
Calibration Curves: Linear Least Squares
For data that follow a straight line, the standard method for fitting is the linear...
Measurement of Air Content in Concrete
The pressure method,...
Atomic Emission Spectroscopy: Overview