Related Experiment Video
Updated: May 4, 2026

Author Spotlight: A Non-Intubated Video-Assisted Thoracoscopic Surgery with Multimodal Analgesia and Sevoflurane Inhalation Anesthesia
Published on: May 26, 2023
Use of extraglottic airways in patients undergoing ambulatory laparoscopic surgery without the need for tracheal
T Suhitharan1, Wendy H L Teoh1
1Department of Women's Anaesthesia, KK Women's and Children's Hospital, Singapore.
Background:
Second generation extraglottic airway devices with gastric access and separate breathing channels have ushered in a new era where their use is increasingly prevalent in surgical patients who would have been traditionally intubated for general anesthesia. New innovations like the i-gel, which is constructed of a thermoplastic elastomer, provide an airtight seal around patient's perilaryngeal anatomy without the inflatable cuff mechanism found in the laryngeal mask airway supreme (LMAS).
Methods:
We conducted a randomized controlled trial comparing the LMAS with the i-gel in 70 anesthetized paralyzed patients undergoing laparoscopic female sterilization. Our primary outcome measure was the oropharyngeal leak pressure (OLP). We studied secondary outcomes of successful first attempt insertion rates, time and ease of the airway and gastric tube insertion, leak fractions and pharyngeal morbidity.
Results:
We found no difference in the OLP between LMAS and i-gel, 25.9 (4.2) versus 24.4 (4.3) s, P=0.153. Both devices had similar first attempt insertion rates (LMAS 94% vs. i-gel 91%) with similar ease and comparable times to achieve an effective airway, LMAS 14.7 (2.7) versus i-gel 16.5 (9.6) s, P=0.306, although gastric tube insertion was easier and faster for the LMAS, 7.9 (1.9) versus i-gel 14.8 (7.7) s, P<0.005. Intraoperatively, there was a significantly greater leak fraction with the i-gel of 0.06 (0.03) versus 0.04 (0.02) with the LMAS, P=0.013. Three patients (8.6%) with LMAS had mild sore throat; one patient (2.9%) had mucosal injury. No complications were documented in the i-gel group.
Conclusions:
Both these extraglottic airway devices offer similar OLPs, high insertion success rates at the first attempt with similar ease and insertion times (albeit longer gastric tube insertion with i-gel). Both provided effective ventilation despite a higher leak fraction with i-gel that was clinically inconsequential.
Related Concept Videos
Cardiopulmonary Resuscitation V: Advanced Airway Management Techniques
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Cardiopulmonary Resuscitation II: ACLS Airway Management
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals....
Tracheostomy: Procedure and Tubes
Tracheostomy tubes can be made of semiflexible plastic (polyurethane or silicone), rigid plastic, or metal, and they come in...