Matrix effect on in-source decay products of peptides in matrix-assisted laser desorption/ionization
Daiki Asakawa1, Motoshi Sakakura2, Mitsuo Takayama2
1Mass Spectrometry Laboratory, Graduate School in Nanobioscience, Yokohama City University ; General and Physical Chemistry Department, Mass Spectrometry Laboratory, University of Liège.
Abstract:
MALDI-ISD of peptides were studied using several salicylic acid derivatives, 2,5-dihydroxybenzoic acid (2,5-DHB), 5-aminosalicylic acid (5-ASA), 5-formylsalicylic acid (5-FSA), and 5-nitrosalicylic acid (5-NSA) as matrices. The difference in the nature of the functional group at the 5-position in the salicylic acid derivatives can dramatically affect the ISD products. The use of 2,5-DHB and 5-ASA leads to "hydrogen-abundant" peptide radicals and subsequent radical-induced N-Cα bonds cleavage. N-Cα bond cleavage gave a c'/z (·) fragment pair and radical z (·)-series fragments gain a hydrogen radical or react with a matrix radical. In contrast, the use of 5-NSA resulted in the production of a "hydrogen-deficient" peptide radical that contained a radical site on the amide nitrogen in the peptide backbone. Subsequently, the radical site on the amide nitrogen induces Cα-C bond dissociation, leading to a (·)/x fragment pair. The a (·)-series ions undergo further hydrogen abstraction to form a-series ions after Cα-C bond cleavage. Since the Pro residue does not contain a nitrogen-centered radical site, Cα-C bond cleavage does not occur. Alternatively, the specific cleavage of CO-N bonds leads to a b (·)/y fragment pair at Xxx-Pro which occurs via hydrogen abstraction from the Cα-H in the Pro residue. The use of 5-FSA generated both a (·)/x- and c'/z (·)-series fragment pairs. An oxidizing matrix provides useful complementary information in MALDI-ISD compared to a reducing matrix for the analysis of amino acid sequencing and site localization in cases of phosphopeptides. MALDI-ISD, when used in conjunction with both reducing and oxidizing matrices is a potentially useful method for de novo peptide sequencing.
More Related Videos
07:49Matrix-assisted Laser Desorption/Ionization Time of Flight MALDI-TOF Mass Spectrometric Analysis of Intact Proteins Larger than 100 kDa
Published on: September 9, 2013
07:12An Efficient Sample Preparation Method to Enhance Carbohydrate Ion Signals in Matrix-assisted Laser Desorption/Ionization Mass Spectrometry
Published on: July 29, 2018
Related Concept Videos
Matrix-Assisted Laser Desorption Ionization (MALDI)
MALDI-TOF Mass Spectrometry
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
Mass Spectrometry: Isotope Effect
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
Chemical Ionization (CI) Mass Spectrometry
