Ultrasound elastography of the liver, spleen, and kidneys in clinically normal cats
Jennifer White1, John Gay, Raelynn Farnsworth
1Department of Veterinary Clinical Sciences, Washington State University, Pullman, WA, 99614.
Abstract:
A large amount of overlap exists in the B-mode ultrasound appearance of normal and abnormal liver, spleen, and kidney tissues in cats. Therefore, invasive tissue sampling procedures remain the standard method for diagnosing diseases in these organs. The purpose of our study was to assess the feasibility of ultrasound elastography as a technique for improving noninvasive characterization of the feline liver, spleen, and kidneys. Elastography was performed on 10 unsedated, clinically healthy cats. Numeric (strain) values (0 = softest to 255 = firmest) assigned to color pixels within regions of interest resulted in median scores (interquartile ranges) of body wall, 207.50 (189.75-224.00); liver, 119.00 (105.00-138.25); spleen, 127.50 (121-00-142.00); right renal cortex, 83.50 (64.00-130.00); right renal near field, 125.50 (110.75-139.75); left renal cortex, 77.50 (52.00-116.25); and left renal near field, 126.00 (114.00-145.25). Strain values were not different between organs. Body wall median was the only significantly different value (P < 0.05). Strain ratio values of body wall:organ were as follows: liver, 1.76 (1.38-2.00); spleen, 1.68 (1.47-1.83); right renal cortex, 2.31 (1.61-3.15); right renal near field, 1.62 (1.41-2.01); left renal cortex, 2.66 (1.45-4.13); and left renal near field, 1.51 (1.29-1.89). Subjectively, hepatic and splenic parenchymal tissues were homogeneous in compressibility and similar in elasticity to one another. Renal cortical tissue was softer compared to medullary tissue. Findings indicated that ultrasound elastography is a feasible technique for objectively and subjectively characterizing the feline liver, spleen, and kidneys. Further research is needed in cats with confirmed diseases of these organs, to compare the diagnostic sensitivity of ultrasound elastography vs. B-mode ultrasonography.
Related Concept Videos
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
Imaging Studies II: Ultrasonography
Ultrasonography
During an ultrasonography procedure, a handheld device called...
Imaging Studies I: Kidney, Ureter, and Bladder Studies
Ultrasound I: Abdominal Ultrasonography
Abdominal ultrasonography, commonly known as abdominal ultrasound, is a vital, non-invasive medical imaging technique widely used in healthcare.
Procedure:
This diagnostic tool allows the clinician to visually inspect internal structures within the abdomen, including vital organs such as the liver, gallbladder, pancreas, kidneys, and spleen.
The abdominal ultrasound process begins with applying a special gel to the patient's skin over the abdomen. This gel enhances the...
Assessment of the Abdomen II: Percussion
Percussion
Percussion is an essential...