Related Experiment Video
Updated: May 4, 2026

Chronic Thromboembolic Pulmonary Hypertension and Assessment of Right Ventricular Function in the Piglet
Published on: November 4, 2015
Right ventricular dysfunction in chronic thromboembolic obstruction of the pulmonary artery: a pressure-volume study
Colm McCabe1, Paul A White, Stephen P Hoole
1Pulmonary Vascular Disease Unit, Papworth Hospital, Cambridge, United Kingdom;
Abstract:
Pressure-volume loops describe dynamic ventricular performance, relevant to patients with and at risk of pulmonary hypertension. We used conductance catheter-derived pressure-volume loops to measure right ventricular (RV) mechanics in patients with chronic thromboembolic pulmonary arterial obstruction at different stages of pathological adaptation. Resting conductance catheterization was performed in 24 patients: 10 with chronic thromboembolic pulmonary hypertension (CTEPH), 7 with chronic thromboembolic disease without pulmonary hypertension (CTED), and 7 controls. To assess the validity of conductance measurements, RV volumes were compared in a subset of 8 patients with contemporaneous cardiac magnetic resonance (CMR). Control, CTED, and CTEPH groups showed different pressure-volume loop morphology, most notable during systolic ejection. Prolonged diastolic relaxation was seen in patients with CTED and CTEPH [tau = 56.2 ± 6.7 (controls) vs. 69.7 ± 10.0 (CTED) vs. 67.9 ± 6.2 ms (CTEPH), P = 0.02]. Control and CTED groups had lower afterload (Ea) and contractility (Ees) compared with the CTEPH group (Ea = 0.30 ± 0.10 vs. 0.52 ± 0.24 vs. 1.92 ± 0.70 mmHg/ml, respectively, P < 0.001) (Ees = 0.44 ± 0.20 vs. 0.59 ± 0.15 vs. 1.13 ± 0.43 mmHg/ml, P < 0.01) with more efficient ventriculoarterial coupling (Ees/Ea = 1.46 ± 0.30 vs. 1.27 ± 0.36 vs. 0.60 ± 0.18, respectively, P < 0.001). Stroke volume assessed by CMR and conductance showed closest agreement (mean bias +9 ml, 95% CI -1 to +19 ml) compared with end-diastolic volume (+48 ml, -16 to 111 ml) and end-systolic volume (+37 ml, -21 to 94 ml). RV conductance catheterization detects novel alteration in pressure-volume loop morphology and delayed RV relaxation in CTED, which distinguish this group from controls. The observed agreement in stroke volume assessed by CMR and conductance suggests RV mechanics are usefully measured by conductance catheter in chronic thromboembolic obstruction.
More Related Videos
07:41Induction and Phenotyping of Acute Right Heart Failure in a Large Animal Model of Chronic Thromboembolic Pulmonary Hypertension
Published on: March 17, 2022
07:56Closed Chest Biventricular Pressure-Volume Loop Recordings with Admittance Catheters in a Porcine Model
Published on: May 18, 2021
Related Concept Videos
Mitral Stenosis I: Introduction
Mitral Regurgitation I: Introduction
Cardiac Catheterization II: Right Heart Catheterization