Interference of gadolinium-based contrast agents on colorimetric calcium assays
Ronald Yan1, Heather Tarr2, Martin McNally3
1Department of Laboratory Medicine, Dr. Everett Chalmers Regional Hospital, Horizon Health Network, Fredericton, New Brunswick, Canada; Dalhousie Medical Program in New Brunswick, Saint John, New Brunswick, Canada.
Objective:
The aim of this study was to evaluate the potential interference of five gadolinium-based contrast agents (GBCAs), gadodiamide (Omniscan®), gadobenate dimeglumine (Multihance®), gadoxetate disodium (Primovist®), gadobutrol (Gadovist®), and gadoteridol (Prohance®), on three clinical laboratory widely used colorimetric calcium assays including the newly developed 5-nitro-5'methyl-l,2-bis(2-aminophenoxy)ethane-N,N,N',N'-tetraacetic acid (NM-BAPTA) method.
Methods:
Plasma was collected from healthy volunteers aged 23-52, and spiked with varying concentrations of the five GBCAs. Calcium determinations were performed in duplicates using the o-cresolphthalein complexone (OCP), arsenazo-III dye, and NM-BAPTA methods on the Roche Integra 400, Abbott Architect 16000, and Roche Modular P automated analyzers respectively.
Results:
Gadobenate dimeglumine, gadobutrol, and gadoteridol did not interfere with any of the assays. There was a small positive bias (8%, p<0.01) at a very high concentration (25mmol/L) of gadoxetate disodium when calcium was assayed using the arsenazo-III method. Gadodiamide at a very high concentration (50mmol/L) induced a significant positive bias (16%, p<0.01) on calcium when measured using the NM-BAPTA method; however a much larger bias (90%, p≪0.01) was observed when calcium was measured using the arsenazo-III method. Significant interferences in calcium measurements using the OCP method began at gadodiamide concentrations as low as 0.5mmol/L (-9%, p<0.01). This negative bias was more pronounced at higher gadodiamide concentrations.
Conclusions:
Of all 5 GBCAs tested, only gadodiamide showed significant interference on the OCP calcium assay at clinically relevant concentrations. The NM-BAPTA assay showed minimum interference with the five GBCAs and demonstrated equal or better performance than the OCP and the arsenazo-III methods in terms of interference with GBCAs.
More Related Videos
13:21Preparation, Purification, and Characterization of Lanthanide Complexes for Use as Contrast Agents for Magnetic Resonance Imaging
Published on: July 21, 2011
11:27Preparation and In Vitro Characterization of Dendrimer-based Contrast Agents for Magnetic Resonance Imaging
Published on: December 4, 2016
Related Concept Videos
Imaging Studies III: Computed Tomography
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System V: CT
Radiological Investigation I: X-ray and CT
Imaging Studies for Cardiovascular System IV: CMRI