Related Experiment Video
Updated: May 4, 2026

Infrared Thermography for the Detection of Changes in Brown Adipose Tissue Activity
Published on: September 28, 2022
Infrared thermography of the udder surface of dairy cattle: characteristics, methods, and correlation with rectal
Moritz Metzner1, Carola Sauter-Louis1, Andrea Seemueller1
1Clinic for Ruminants with Ambulatory and Herd Health Services, Ludwig-Maximilians-Universität Munich, Sonnenstr. 16, D-85764 Oberschleissheim, Germany.
Abstract:
Thermograms of the caudal udder surface were taken of five healthy cows before and after inoculation of Escherichia coli into the right hind quarter. Images in clinically normal udder quarters from cows without fever (CN) were compared with those post inoculation when cows had fever (⩾ 39.5°C) and showed elevation of somatic cell counts (⩾ 400,000 cells/mL) in the inoculated quarter (CM). Using graphic software tools, different geometric analysis tools (GATs: polygons, rectangles, lines) were set within the thermographic images. The following descriptive parameters (DPs) were employed: minimum value ('min'), maximum value ('max'), range ('max-min'), and arithmetic mean ('am'). Surface temperatures in group CN were between 34.1°C ('polygons'/'min') and 37.9°C ('polygons'/'max'), and in group CM between 34.5°C ('polygons'/'min') and 40.0°C ('polygons'/'max'). The greatest differences in the temperatures between CN and CM (2.06°C) were found in 'polygons' and 'rectangles' using 'max'. The smallest coefficient of variation in triplicate determinations was found in GAT 'polygons' with DP 'max' (Tmax) (0.15%), and the relationship to the rectal body temperature (Tr) could be described by Tr=5.68+0.874*Tmax. The results show that significant changes can be displayed best using the GAT 'polygons' and the DP 'max'. These methods should be considered for automated monitoring of udder health in dairy cows.
Related Concept Videos
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Body Temperature

