Influence of rigid coregistration of PET and CT data on metabolic volumetry: a user's perspective
Ingo G Steffen1, Frank Hofheinz, Julian Mm Rogasch
1Klinik für Radiologie und Nuklearmedizin, Universitätsklinikum Magdeburg A,ö,R, Leipziger Strasse 44, Magdeburg 39120, Germany. ingo.steffen@med.ovgu.de.
Background:
While non-rigid fusion is by definition expected to alter the information of positron emission tomography (PET) data, we assessed whether rigid transformation also influences metabolic tumor volume (MTV) determination.
Methods:
The PET/computed tomography (CT) data of 28 solid pulmonary lesions of 20 tumor patients examined with 18 F-Fluordeoxyglucose (FDG) was retrospectively analyzed. The original (OR) hardware-coregistered PET images were fused with contrast-enhanced diagnostic CT (CT1, 1 mm slices) and low dose CT (CT5, 5 mm slices). After automatic rigid transformation (Mirada Fusion7D) using two algorithms (rigid fast (RF), rigid slow (RS)), MTV and maximal standardized uptake value (SUVmax) were determined applying four different segmentation methods with either fixed or background-adapted thresholding and compared to OR-PET data.
Results:
Relative differences in SUVmax compared to OR data revealed no significant differences for RF (median, -0.1%; interquartile range (IQR), -1.1% to 0.9%; p = 0.75) and RS (median, 0.5%; IQR, -0.6% to 1.3%; p = 0.19) in CT1, whereas in CT5 significant deviations were observed for RF (median, -9.0%; IQR, -10.9 to -6.1; p < 0.001) and RS (median, -8.4%; IQR, -11.1 to -5.6; p < 0.001). Relative MTV differences were 0.7% (IQR, -3.0% to 2.7%; p = 0.76) for RF and -1.3% (IQR, -3.6% to 0.9%; p = 0.12) for RS in CT1. Coregistration led to significant MTV differences in RF (median, 10.4%; IQR, 7.4% to 16.7%; p < 0.001) and RS (median, 10.6%; IQR, 5.4% to 17.7%; p < 0.001) in CT5.
Conclusions:
Rigid coregistration of PET data allows a quantitative evaluation with reasonable accuracy in most cases. However, in some cases, it can result in substantial deviations of MTV and SUVmax. Therefore, it is recommended to perform quantitative evaluation in the original PET data rather than in coregistered PET data.
More Related Videos
08:02Author Spotlight: Enhanced Quantification of Cardiovascular Calcification Progression for Longitudinal Micro PET/CT Studies in Small Research Animals
Published on: November 15, 2024
07:13Author Spotlight: An Efficient and Robust Software for Automated Fusion of Multiple Preclinical Imaging Modalities
Published on: October 27, 2023
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Imaging Studies for Cardiovascular System V: CT
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Imaging Studies for Cardiovascular System IV: CMRI