Related Experiment Video
Updated: May 4, 2026

Author Spotlight: Advancements in Refractive Surgical Correction for Presbyopia and Exploring Postoperative Visual Acuity
Published on: September 20, 2024
Outcome of posterior chamber phakic intraocular lens procedure to correct myopia
Nasser Al Sabaani1, Abdullah Al Assiri1, Abdullah Al Torbak1
1Anterior Segment Division, King Khaled Eye Specialist Hospital, Riyadh, Saudi Arabia.
Purpose:
To assess the safety and efficacy of the implantable contact lens (ICL™) to treat myopia.
Design:
Clinical, retrospective, single center, non-randomized case series.
Participants:
Sixty-nine eyes of 46 patients with myopia ranging from -3.00 to 25.00 D were included in this study.
Intervention:
Implantation of the ICL™.
Main Outcome Measures:
Uncorrected Visual Acuity (UCVA), refraction, best spectacle corrected visual acuity (BSCVA), adverse events, operative and postoperative complications, subjective assessment and symptoms.
Results:
The mean follow-up was 12.35 ± 6.13 (SD) months (range, 6 months-32 months). At the last visit, 49.20% of eyes had 20/20 or better UCVA compared to preoperative 20/20 or better BSCVA of 31.9% of eyes; 69.23% of eyes had postoperative UCVA better than or equal to preoperative BSCVA. The mean manifest refractive cylinder was 1.93 ± 1.21 D at baseline and 1.00 ± 0.92 D postoperatively. The mean manifest refraction spherical equivalent (MRSE) was -11.70 ± 4.24 D preoperatively and -0.69 ± 1.13 D postoperatively. A total of 69.8% of eyes were within ±0.5 D of the predicted MRSE; 84.1% were within ±1.0 D, and 88.90% were within ±2.0 D. BSCVA of 20/20 or better was achieved in 64.6% of eyes postoperatively, compared to 31.9% preoperatively. Mean improvement in BSCVA was 1line. One eye (1.5%) lost ⩾2 lines of BSCVA at the last visit, whereas 20% of eyes improved by ⩾2 lines. A total of 56.92% of cases gained ⩾1 line of BSCVA and 4.62% of cases lost ⩾1 line. Four ICL lenses were removed without significant loss of BSCVA, and 2 eyes with clinically significant lens opacities were observed. Four eyes (5.8%) developed a pupillary block the first day postoperatively. One eye (1.4%) developed a hypotony and AC shallowing.
Conclusion:
Implantation of ICL for the correction of myopia was a safe procedure with good visual and refractive results from the early postoperative period to 1 year. Long-term follow-up is required to confirm the long-term safety of this implant.
More Related Videos
04:59Author Spotlight: Enhancing Visual Outcomes in Cataract Surgery: A Novel Technique to Prevent Posterior Capsular Opacification Through IOL Rotation
Published on: July 7, 2023
05:14Comparison of Agreement and Accuracy using Binocular Wavefront Optometer with Autorefractor and Phoropter
Published on: September 16, 2025
Related Concept Videos
Focusing of Light in the Eye
Angle Closure Glaucoma: Treatment
Glaucoma: Overview
Open Angle Glaucoma: Treatment
Drugs such as carbonic anhydrase inhibitors, α2- and...