Related Experiment Video
Updated: May 4, 2026

Hydrophobic Salt-modified Nafion for Enzyme Immobilization and Stabilization
Published on: July 11, 2012
Performance of enzymatic fuel cell in cell culture
P Lamberg1, S Shleev2, R Ludwig3
1Department of Biomedical Sciences, Faculty of Health and Society, Malmö University, 20506 Malmö, Sweden.
Abstract:
Here we present the very first study of an enzymatic fuel cell (EFC) in a cell culture. An EFC with Corynascus thermophilus cellobiose dehydrogenase (CDH) based bioanode and Myrothecium verrucaria bilirubin oxidase (BOx) based biocathode was constructed at the bottom of a medusa cell culture plate. The constructed EFC had a power density of up to 25 μW cm(-2) at 0.5 V potential in simple buffer solution and in cell culturing medium. L929 murine fibroblast cells were seeded on top of the EFC and possible effects of the EFC on the cells and vice versa were studied. It was shown that on average the power of the EFC drops by about 70% under a nearly confluent layer of cells. The EFC appeared to have a toxic effect on the L929 cell line. It was concluded that the bioanode, consisting of CDH, produced hydrogen peroxide at toxic concentrations. However, the toxic effect was circumvented by co-immobilizing catalase on the bioanode.