Objective:
To assess if B-flow ultrasound improves visualization of flow of contrast medium in the Fallopian tubes during hysterosalpingo-contrast sonography (HyCoSy) compared with grayscale ultrasound.
Methods:
This prospective observational study included 160 women referred for HyCoSy as part of infertility work-up between January 2011 and September 2012. In each woman, at the same session, HyCoSy was performed first using saline with air and then using Sonovue®, and for each contrast medium, grayscale ultrasound was first used and then B-flow ultrasound was used. Flow of contrast was observed in three parts of each tube: intramural, middle and distal.
Results:
In 129 (81%) women, flow of Sonovue was observed in the intramural part of both tubes and in the pouch of Douglas when using grayscale ultrasound. In these women, flow of Sonovue was seen in the middle part of 70% of the 258 tubes when using grayscale ultrasound and in 93% when using B-flow ultrasound; and in the distal part in 81% when using grayscale ultrasound and in 98% when using B-flow ultrasound. When using air and saline, flow was seen in the intramural part of 90% and 93% of the tubes, in the middle part in 54% and 72%, and in the distal part in 66% and 90%, using grayscale ultrasound and B-flow ultrasound, respectively.
Conclusion:
B-flow ultrasound facilitates detection of flow of contrast in the middle and distal parts of the tubes at HyCoSy, especially when a mixture of saline and air is used as contrast medium.
Related Concept Videos
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for...
Ultrasonography
During an ultrasonography procedure, a handheld device called...
Imaging Studies II: Ultrasonography
Imaging Studies VI: Voiding Cystourethrography and Cystography
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
Blood Flow