Resolving Water, Proteins, and Lipids from In Vivo Confocal Raman Spectra of Stratum Corneum through a Chemometric Approach
Published on: September 26, 2019
Confocal Raman characterization of different protein desorption behaviors from chromatographic particles
Yuewu Xiao1, Thomas Stone, Wilson Moya
1EMD Millipore , 80 Ashby Road, Bedford, Massachusetts 01730, United States.
Abstract:
Confocal Raman spectroscopy is a nondestructive analytical technique that combines the chemical information from vibrational spectroscopy with the spatial resolution of confocal microscopy. It was applied, for the first time, to measure protein desorption from chromatographic particles. Monoclonal antibody was loaded onto the Fractogel EMD SO3 (M) cation exchanger at either pH 5 or pH 4. Confocal Raman measurement suggests that only the protein loaded at pH 5 is able to release from chromatographic particles in the elution buffer. Detailed comparison of high-quality spectra indicates that, while proteins loaded at both pH values showed a predominant β-sheet conformation, protein loaded at pH 4 has a broader amide I band with more intensity in the >1680 cm(-1) region. This small but clear and reproducible amide I bandwidth increase is not observed for protein in the solution state at pH 4. No definitive assignment of the increased Raman intensity in the >1680 cm(-1) region could be made, but it might be related to structural changes involved in the association of protein molecules in the adsorbed state, which helps to explain the nearly 100% retention under elution conditions of the monoclonal antibody adsorbed at pH 4 in chromatographic particles.
Related Concept Videos
Raman Spectroscopy: Overview
However, a small fraction of the scattered light exhibits a frequency shift due to the exchange of energy between the incident photons and...
Protein Dynamics in Living Cells
Fluorescent recovery after photobleaching (FRAP) is a fluorescent-protein-based detection technique used to quantify protein movement rates within the cell. This method exposes a small portion of the cell to an intense laser beam. The laser beam causes permanent photobleaching of the fluorophore-tagged proteins in the exposed region. As the bleached...
Raman Spectroscopy Instrumentation: Overview
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
Types Of Column Chromatography
Gel Filtration Chromatography
When the...