Related Experiment Video
Updated: May 4, 2026

PET and MRI Guided Irradiation of a Glioblastoma Rat Model Using a Micro-irradiator
Published on: December 28, 2017
Radiation exposure in perfusion CT of the brain
Adrian Ringelstein1, Ursula Lechel, Delia M Fahrendorf
1From the *Institute of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Essen; and †Department of Medical and Occupational Radiation Protection, Federal Office for Radiation Protection, Neuherberg, Germany.
Objective:
This study aimed to show the simulation of the radiation exposure of the brain during perfusion measurements multi-detector-CT.
Material And Methods:
The effective dose and different organ doses were measured with thermoluminescent dosimeters in an Alderson-Rando phantom and compared with the data of a simulation program (CT-Expo V1.6) for varying scan protocols with different tube voltages (in kilovolts) and constant parameters for tube current (270 mAs), scan length (28.8 mm), scan time (40 seconds), slice thickness (24 × 1.2 mm), and number of scans (40) for multi-detector-CT perfusion measurements of the brain.
Results:
The thermoluminescent dosimeter measurements yielded effective doses of 3.8 mSv (80 kV), 8.6 mSv (100 kV), 14.1 mSv (120 kV), and 22.2 mSv (140 kV). These values were in line with the data from the simulation program CT-Expo V1.6. The organ doses varied between 97 and 556 mGy (brain), 10.7 and 80.9 mGy (eye lens), 9.6 and 46 mGy (bone marrow), 1.2 and 6.7 mGy (thyroid gland), and 4.1 to 22.3 mGy (skin). The maximum local skin dose ranged from 355 mGy (80 kV) to 1855 mGy (140 kV) in the directly exposed part of the skin.
Conclusions:
The radiation exposure during perfusion measurements of the brain is strongly dependent on the tube voltage and can vary widely even if the other exposure parameters remain constant. Maximum organ doses up to 556 mGy (brain) can be measured. Even if we never reached local organ doses that can cause a direct radiation injury, the review of the tube voltages implemented by the vendor is mandatory beside the limitation of the scanned area by clinical examination and the reduction of the number of scans. Simulation programs are a valuable tool for dose measurements.
More Related Videos
08:36Multi-Tracer Studies of Brain Oxygen and Glucose Metabolism Using a Time-of-Flight Positron Emission Tomography-Computed Tomography Scanner
Published on: June 7, 2024
13:16Intravascular Perfusion of Carbon Black Ink Allows Reliable Visualization of Cerebral Vessels
Published on: January 4, 2013
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Imaging Studies for Cardiovascular System V: CT