Related Experiment Video
Updated: May 4, 2026

Measuring 3D In-vivo Shoulder Kinematics using Biplanar Videoradiography
Published on: March 12, 2021
Validation protocol for assessing the upper cervical spine kinematics and helical axis: An in vivo preliminary
Pierre-Michel Dugailly1, Stéphane Sobczak2, Alphonse Lubansu2
1Laboratory of Functional Anatomy, Department of Physiotherapy and Rehabilitation, Faculty of Motor Sciences, Free University of Brussels, Brussels, Belgium ; Research Unit of Osteopathy, Department of Osteopathic Sciences, Faculty of Motor Sciences, Free University of Brussels, Brussels, Belgium.
Context:
The function of the upper cervical spine (UCS) is essential in the kinematics of the whole cervical spine. Specific motion patterns are described at the UCS during head motions to compensate coupled motions occurring at the lower cervical segments.
Aims:
First, two methods for computing in vitro UCS discrete motions were compared to assess three-dimensional (3D) kinematics. Secondly, the same protocol was applied to assess the feasibility of the procedure for in vivo settings. Also, this study attempts to expose the use of anatomical modeling for motion representation including helical axis.
Settings And Design:
UCS motions were assessed to verify the validity of in vitro 3D kinematics and to present an in vivo procedure for evaluating axial rotation.
Materials And Methods:
In vitro kinematics was sampled using a digitizing technique and computed tomography (CT) for assessing 3D motions during flexion extension and axial rotation. To evaluate the feasibility of this protocol in vivo, one asymptomatic volunteer performed an MRI kinematics evaluation of the UCS for axial rotation. Data processing allowed integrating data into UCS 3D models for motion representation, discrete joint behavior, and motion helical axis determination.
Results:
Good agreement was observed between the methods with angular displacement differences ranging from 1° to 1.5°. Helical axis data were comparable between both methods with axis orientation differences ranging from 3° to 6°. In vivo assessment of axial rotation showed coherent kinematics data compared to previous studies. Helical axis data were found to be similar between in vitro and in vivo evaluation.
Conclusions:
The present protocol confirms agreement of methods and exposes its feasibility to investigate in vivo UCS kinematics. Moreover, combining motion analysis, helical axis representation, and anatomical modeling, constitutes an innovative development to provide new insights for understanding motion behaviors of the UCS.
Related Concept Videos
Articulations of the Vertebral Column
Relative Motion Analysis using Rotating Axes
However, to express the relative position of point B relative to point A, an additional frame of reference, denoted as x'y', is necessary. This additional frame not only translates but also rotates relative to the fixed frame, making it...
Relative Motion Analysis using Rotating Axes-Problem Solving
Here, in order to determine the magnitude of velocity and acceleration for point...
Eccentric Axial Loading in a Plane of Symmetry
Kinematic Equations for Rotation
For instance, imagine a point A on a rigid body engaged in circular motion. The translational velocity of this particular point can be calculated by taking the time derivatives of the displacement equation, which essentially measures the...