Related Experiment Video
Updated: May 4, 2026

The WATCHMAN Left Atrial Appendage Closure Device for Atrial Fibrillation
Published on: February 28, 2012
Detection of atrial fibrillation after ischemic stroke or transient ischemic attack: a systematic review and
Amit Kishore1, Andy Vail, Arshad Majid
1From the Stroke and Vascular Research Centre, Institute of Cardiovascular Sciences (A.K., P.J.T., C.J.S.) and Centre for Biostatistics (A.V.), University of Manchester, Manchester Academic Health Science Centre, Salford Royal Foundation Trust, Salford, United Kingdom; Greater Manchester Comprehensive Stroke Centre, Department of Medical Neurosciences, Salford Royal Foundation Trust, Salford, United Kingdom (A.K., A.M., P.J.T., C.J.S.); and Institute of Cardiovascular and Medical Sciences, University of Glasgow, Western Infirmary, Glasgow, United Kingdom (J.D., K.R.L.).
Background And Purpose:
Atrial fibrillation (AF) confers a high risk of recurrent stroke, although detection methods and definitions of paroxysmal AF during screening vary. We therefore undertook a systematic review and meta-analysis to determine the frequency of newly detected AF using noninvasive or invasive cardiac monitoring after ischemic stroke or transient ischemic attack.
Methods:
Prospective observational studies or randomized controlled trials of patients with ischemic stroke, transient ischemic attack, or both, who underwent any cardiac monitoring for a minimum of 12 hours, were included after electronic searches of multiple databases. The primary outcome was detection of any new AF during the monitoring period. We prespecified subgroup analysis of selected (prescreened or cryptogenic) versus unselected patients and according to duration of monitoring.
Results:
A total of 32 studies were analyzed. The overall detection rate of any AF was 11.5% (95% confidence interval, 8.9%-14.3%), although the timing, duration, method of monitoring, and reporting of diagnostic criteria used for paroxysmal AF varied. Detection rates were higher in selected (13.4%; 95% confidence interval, 9.0%-18.4%) than in unselected patients (6.2%; 95% confidence interval, 4.4%-8.3%). There was substantial heterogeneity even within specified subgroups.
Conclusions:
Detection of AF was highly variable, and the review was limited by small sample sizes and marked heterogeneity. Further studies are required to inform patient selection, optimal timing, methods, and duration of monitoring for detection of AF/paroxysmal AF.
More Related Videos
28:13Catheter Ablation in Combination With Left Atrial Appendage Closure for Atrial Fibrillation
Published on: February 26, 2013
08:10Estimating Bilateral Atrial Function by Cardiovascular Magnetic Resonance Feature Tracking in Patients with Paroxysmal Atrial Fibrillation
Published on: July 20, 2022
Related Concept Videos
Acute Coronary Syndrome III: Diagnostic Studies
Transient Ischemic Attack l: Introduction
Ischemic Stroke l: Introduction
Ischemic Stroke ll: Pathophysiology
Atherosclerosis II: Clinical Manifestations and Diagnostic Tests
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT