Related Experiment Video
Updated: May 4, 2026

Magnetic Resonance Imaging Quantification of Pulmonary Perfusion using Calibrated Arterial Spin Labeling
Published on: May 30, 2011
Assessing reperfusion with whole-brain arterial spin labeling: a noninvasive alternative to gadolinium
Raymond V Mirasol1, Reinoud P H Bokkers, Daymara A Hernandez
1From the Section on Stroke Diagnostics and Therapeutics, National Institute of Neurological Disorders and Stroke, National Institutes of Health, Bethesda, MD (R.V.M., D.A.H., J.G.M., M.L., S.W., L.L.L.); Department of Neurobiology, Care Sciences and Society, Division of Neurodegeneration, The Karolinska Institute, Stockholm, Sweden (R.V.M.); Department of Radiology, University Medical Center Utrecht, Utrecht, The Netherlands (R.P.H.B.); Department of Radiology, Gelre Hospitals, Apeldoorn, The Netherlands (R.P.H.B.); Research Scholars Program, Howard Hughes Medical Institute, Bethesda, MD (R.V.M.); Department of Neurology and Neurotherapeutics, Seton/UT Southwestern Clinical Research Institute of Austin, UT Southwestern Medical Center, TX (S.W.); and Johns Hopkins Community Physicians, Bethesda, MD (J.G.M.).
Background And Purpose:
Arterial spin labeling (ASL) is a perfusion imaging technique that does not require gadolinium. The study aimed to assess the reliability of ASL for evaluating reperfusion in acute ischemic stroke in comparison with dynamic susceptibility contrast (DSC) imaging.
Methods:
The study included 24 patients with acute ischemic stroke on admission and 24-hour follow-up ASL and DSC scans. Two readers rated images for interpretability and evidence of reperfusion. Cohen unweighted κ was used to assess (1) inter-rater reliability between readers for determining interpretability and the presence of reperfusion, (2) agreement between ASL and DSC for determining reperfusion for individual raters, and (3) agreement between ASL and DSC for determining reperfusion after consensus.
Results:
Inter-rater reliability for both ASL and DSC was moderate to good (κ of 0.67 versus 0.55, respectively). Reader 1 rated 16 patients as having interpretable ASL and DSC when compared with 15 patients for reader 2. The κ between ASL and DSC for determining reperfusion was 0.50 for reader 1 and 0.595 for reader 2. After consensus, 18 ASL and 17 DSC image sets were rated interpretable for reperfusion and 13 had both interpretable ASL and DSC scans, yielding a κ for assessment of reperfusion of 0.8.
Conclusions:
Inter-rater reliability of ASL and DSC was moderate to good. Agreement between ASL and DSC for determining reperfusion was moderate for each individual rater and increased substantially after consensus. ASL is a noninvasive and practical alternative to DSC for reperfusion assessments in patients with confirmed acute ischemic stroke.
More Related Videos
05:23Author Spotlight: Noninvasive Cerebral Blood Flow Determination in Human Functional Brain Region for Diagnosis of Neurological Disorders
Published on: May 31, 2024
09:59A Magnetic Resonance Imaging Protocol for Stroke Onset Time Estimation in Permanent Cerebral Ischemia
Published on: September 16, 2017
Related Concept Videos
Magnetic Resonance Imaging
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...