Objective:
Coagulation tests are influenced by pre-analytic conditions such as blood collection systems. Change of glass collection tubes with plastic ones will cause alteration of the test results. The aim of this study was to compare three plastic blood collection tubes with a standard glass blood collection tube and each plastic collection tube with the other two for possible additional tube-to- tube differences.
Material And Methods:
A total of 284 blood samples were obtained from 42 patients receiving warfarin during their routine controls, besides 29 healthy volunteers. Subgroup analyses were done according to health status.
Results:
Our study demonstrated that different blood collection tubes have a statistically significant influence on coagulation tests. The magnitude of the effect depends on the tube used. However most of the tests performed on samples obtained from any tube correlated significantly with results obtained from other tube samples.
Conclusion:
Although blood collection tubes with different brands or properties will have distinct effects on coagulation tests, the influence of these blood collection tubes may be relatively small to interfere with decision-making on dose prescription, therefore lack clinical importance. Correlations between the results showed that, one of these plastic blood collection tubes tested in our study, can be used interchangably for a wide variety of coagulation assays.
Conflict Of Interest:
None declared.
More Related Videos
09:38A Microfluidic Flow Chamber Model for Platelet Transfusion and Hemostasis Measures Platelet Deposition and Fibrin Formation in Real-time
Published on: February 14, 2017
08:01The Nijmegen Hemostasis Assay: Simultaneous Fluorogenic Measurement of Thrombin and Plasmin Generation in a Single Well
Published on: February 27, 2026
Related Concept Videos
Blood Transfusion and Agglutination
History
The history of blood transfusion dates back to the 17th century, when early attempts were made in animals. In 1818 James Blundell, a British doctor, performed the first successful human blood transfusion. Later in 1900, Karl...
Blood Transfusion
Blood Transfusion Overview
A blood transfusion is a medical procedure used to replace blood lost due to injury, surgery, or to treat conditions such as anemia or cancer. During a transfusion, donor blood is...
Disorders of Hemostasis
Thromboembolic Disorders
Two factors primarily cause thromboembolic conditions.
Extrinsic and Intrinsic Pathways of Hemostasis
The Extrinsic Pathway
The extrinsic pathway of coagulation is typically initiated by tissue damage that exposes blood to tissue factor (TF), a protein released by the damaged tissue cells outside the blood vessels—this interaction with TF triggers biochemical reactions involving specific clotting factors. The key player here is Factor VII, which...
Blood Typing
Antigens are protein molecules that reside on the surface of red blood cells (RBCs). The ABO and Rh blood typing systems target...
Blood Studies I: ABG and VBG
Arterial Blood Gas (ABG)
Arterial Blood Gas (ABG) studies are crucial for assessing the lungs' ability to supply oxygen and remove carbon dioxide, reflecting the patient's ventilation status. They also help understand the kidneys' capacity to...