Impact of low filter resistances on subjective and physiological responses to filtering facepiece respirators

Raymond J Roberge1, Jung-Hyun Kim1, Jeffrey B Powell1

  • 1Technology Research Branch, National Personal Protective Technology Laboratory, National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention, Pittsburgh, Pennsylvania, United States of America.

Plos One
|January 4, 2014
PubMed

Related Concept Videos

Factors Affecting Pulmonary Ventilation01:19

Factors Affecting Pulmonary Ventilation

Besides the pressure difference between the external environment and the lungs, the airflow rate and ease of pulmonary ventilation are also influenced by three other factors: surface tension of the fluid in the alveoli, compliance of the lungs, and airway resistance.
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...
3.2K
Passive Filters01:27

Passive Filters

Passive filters are utilized to shape the frequency spectrum of signals across a diverse array of applications. These filters, using only passive elements like resistors (R), inductors (L), and capacitors (C), are capable of selectively allowing or blocking certain frequency ranges without the need for external power sources.
Low-Pass Filters
Low-pass filters are designed to transmit signals with frequencies lower than the cutoff frequency, ωc, and attenuate those above it. The cutoff...
1.2K
Filtration00:53

Filtration

Filtration is a physical separation process that involves passing a suspension through a porous medium to separate solids from fluids. During filtration, solids collect on the porous medium while liquids, also collectively known as the filtrate, pass through. The filtration medium is selected based on the filtration purpose, quantity, and nature of the precipitate. The general criteria for a suitable filtering medium are that it is inert, mechanically strong, nonabsorbent toward dissolved...
4.5K
Oxygen Delivering System I: Nasal Cannula and Face Mask01:26

Oxygen Delivering System I: Nasal Cannula and Face Mask

The human body requires oxygen to function, and when the natural process of respiration is hindered, external devices, including the following, are needed to help deliver this vital gas.
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
2.7K
Physiological Control of Respiration01:23

Physiological Control of Respiration

Introduction
Breathing, a seemingly passive process, is regulated by the respiratory center in the brainstem. This center coordinates the involuntary control of respirations, which means it occurs without conscious effort, ensuring a smooth and uninterrupted pattern.
Regulation of Ventilation
The body maintains ventilation by monitoring levels of carbon dioxide (CO2), oxygen (O2), and hydrogen ion concentration (pH) in the arterial blood. Among these factors, the level of CO2 plays a crucial...
5.0K
Active Filters01:25

Active Filters

Active filters are electronic circuits that use operational amplifiers (op-amps), resistors, and capacitors to filter out unwanted frequency components from a signal. A first-order low-pass active filter is designed to pass signals with a frequency lower than a certain cutoff frequency and attenuate frequencies higher than that cutoff frequency. The transfer function for a first-order low-pass active filter is:
1.4K