Related Experiment Video
Updated: May 4, 2026

High-Resolution Endocardial and Epicardial Optical Mapping in a Sheep Model of Stretch-Induced Atrial Fibrillation
Published on: July 29, 2011
Transverse versus longitudinal electrical propagation within the atrioventricular node during dual pathway
1Department of Biomedical Sciences, New York Institute of Technology College of Osteopathic Medicine, Old Westbury, NY, USA.
Background:
We have discovered and validated that AV node dual pathway conduction results in a new phenomenon termed His electrogram alternans (HEA), which indicates dual inputs rather than a final common pathway from the AV node into the His bundle. However, the electrophysiological basis for AV node dual pathway conduction and HEA has not been clarified. This study was designed to elucidate the electrophysiological basis for dual pathway conduction and HEA.
Methods:
By using HEA as an index of dual pathway electrophysiology, action potentials from multiple locations in the superior and inferior AV nodal domains were obtained to monitor electrical propagation during dual pathway conduction in 8 isolated rabbit hearts.
Results:
Fibers inside the AV node were generally aligned along the AV conduction axis. During fast pathway (FP) conduction, electrical excitation in the AV node was propagated in a superior to inferior direction across the major fiber orientation. In contrast, slow pathway (SP) conduction occurred when the superior-inferior propagation failed within the superior nodal domain, permitting electrical propagation to proceed in the inferior nodal domain along the fiber orientation in a posterior to anterior direction. In effect, FP activated first the superior distal node, while SP activated first the inferior distal node. This functional dissociation of superior-fast and inferior-slow domains in distal node produced dual inputs into the His bundle.
Conclusions:
Transverse versus longitudinal electrical propagation within the AV node produces functional dissociation in the distal node, resulting in superior-fast and inferior-slow inputs into the His bundle and HEA during dual pathway conduction.
Related Concept Videos
Electrophysiology of Normal Cardiac Rhythm
Conduction System of the Heart
The pacemaker cells are located in two primary nodes: the sinoatrial (SA) node and the atrioventricular (AV) node. The SA node pacemaker cells can autonomously depolarize, triggering an action potential that leads to the...
Conduction System of the Heart
This system relies on the unique properties of nodal and Purkinje cells:...
ECG Interpretation of Arrhythmias II: Atrial, Junctional and Ventricular Arrhythmias
Mechanism of Cardiac Arrhythmias
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...

