Related Experiment Video
Updated: May 4, 2026

Use of a Percutaneous Ventricular Assist Device/Left Atrium to Femoral Artery Bypass System for Cardiogenic Shock
Published on: August 16, 2021
De novo aortic insufficiency during long-term support on a left ventricular assist device: a systematic review and
Salil V Deo1, Vikas Sharma, Yang Hyun Cho
1From the *Adventist Wockhardt Heart Institute, Surat, Gujarat, India; †Division of Cardiovascular Surgery, Mayo Clinic, Rochester, Minnesota; ‡Division of Cardiovascular Surgery, Samsung Medical Center, Sungkyunkwan School of Medicine, Seoul, South Korea; and §Department of Surgery, University of Minnesota, Minneapolis, Minnesota.
Abstract:
Aortic insufficiency (AI) may occur while supported on a left ventricular assist device (LVAD). We conducted a systematic review to determine the incidence, predictors, and consequences of AI during LVAD support. MEDLINE was searched for original studies presenting clinical data regarding patients who developed AI during LVAD implant. Seven observational studies (657 patients) were selected for review; 65% of patients underwent implantation with a continuous-flow device (Cf-LVAD). The incidence of AI was 25% (11-42%) (Support period: 412 ± 281 days). AI increased by 4% (1-6%) per month of support (p < 0.01). AI-positive patients were older at implant (weighted mean difference, 7.7 [4.3; 11.1]; p < 0.01). Female sex (0.002 ± 0.001; p = 0.01) and smaller body surface area (-0.003 ± 0.001 per m; p < 0.01) correlated with progressive AI. Destination therapy patients (odds ratio [OR], 5.3 [1.2, 24]; p = 0.02) and those with Cf-LVAD pumps were likely to develop AI (hazard ratio [HR], 2.2 [1.2, 3.8]; p < 0.01). A closed aortic valve was associated with AI (OR, 4.7 [1.9, 11.8]; p < 0.01). Survival was comparable in both cohorts (HR, 1.5 [0.81, 2.8]; p = 0.2). A significant number of patients develop de novo AI during LVAD support. Advanced age, longer support duration, continuous-flow pumps, and a closed aortic valve are associated with AI. Large cohort studies would improve our understanding of this condition.
More Related Videos
05:18Implantation of Left Ventricular Assist Device (LVAD) in Juvenile Landrace Swine: A LVAD Implantation Model of Pediatric Heart Failure
Published on: January 16, 2026
07:24Reduction in Left Ventricular Wall Stress and Improvement in Function in Failing Hearts using Algisyl-LVR
Published on: April 8, 2013
Related Concept Videos
Aortic Regurgitation III: Medical Management
Aortic Regurgitation I: Introduction
Cardiomyopathy V: Interprofessional Care
Heart Failure II: Pathophysiology
Mitral Stenosis III: Medical Management
Heart Failure VI: Adjunct Therapies