Three-dimensional T2-weighted imaging for liver MRI: clinical values of tissue-specific variable refocusing
Yukihisa Takayama1, Akihiro Nishie, Yoshiki Asayama
1Department of Molecular Imaging and Diagnosis, Graduate School of Medical Sciences, Kyushu University, Higashi-ku, Fukuoka City, Fukuoka, Japan.
Purpose:
To assess the clinical utility of tissue-specific variable refocusing flip-angle (VRFA) turbo-spin echo imaging for three-dimensional T2-weighted imaging (3D-T2WI) of the liver.
Materials And Methods:
Fifty-nine patients were scanned with three types of fat-suppressed T2WI for the comparison: two-dimensional single-shot turbo spin echo T2WI (ssT2WI), 3D-T2WI with tissue-specific VRFA (VISTA-TSV), and 3D-T2WI with low-constant VRFA (VISTA). Qualitatively, artifacts in the left and right lobes of the liver and black-blood effects in the liver were compared using the Wilcoxon signed-rank test with the Bonferroni correction. The detection and correct characterization rates of liver lesions were compared using McNemar's test.
Results:
VISTA-TSV showed reduced artifacts in the left and right lobes of the liver compared with VISTA (P < 0.017). The artifacts shown by VISTA-TSV were equivalent to those shown by ssT2WI. The black-blood effects of VISTA-TSV and VISTA were better than that of ssT2WI (P < 0.017). VISTA-TSV showed the best detection and correct characterization rate of liver lesions among the three imaging techniques (P < 0.05).
Conclusion:
3D-T2WI with tissue-specific VRFA can reduce artifacts of the liver, sufficiently suppress the signal in blood vessels, and has a potential to improve the detection and correct characterization rates of liver lesions.