Background:
For the treatment of proximal humeral fractures two major therapeutic principles can be employed: intramedullary nailing (PHN) or locking plate osteosynthesis. The aim of this study was to evaluate and compare clinical and radiological long-term outcome of proximal humeral fracture stabilization using PHN or angular stable plating.
Materials And Methods:
In a retrospective study between March 2009 and March 2010, we analyzed 72 out of 118 patients with unified proximal humeral fracture who had been treated at least 3 years previously using PHN (44 patients) or angular stable plating (28 patients) in a level 1 trauma center. Functional and radiological outcomes were assessed at least 3 years after trauma using the Constant and Murley score and SF-36 score.
Results:
According to the Neer classification, there were 31 3-part fractures (PHN: 23; plate: 8) and 41 4-part fractures (PHN: 21; plate: 20), respectively. No clinical symptoms after 3 years were observed in 42 patients, whereas in 30 patients clinical symptoms were evaluated related to pain and/or loss of function. Functional outcome using the Constant and Murley score demonstrated a total score of 73 points (ipsilateral side) vs. 88 points (contralateral side) in all evaluated patients, on average.
Conclusion:
Both PHN and angular stable plating are adequate treatment options for proximal humeral fractures. Both systems require precise preoperative planning and advanced surgical experience. No significant differences in long-term clinical and radiological outcome between implants regarding fracture classification, age of patient, and choice of implant were found.