Integration of MDCT and fluoroscopy using C-arm computed tomography to guide structural cardiac interventions in the
Amar Krishnaswamy1, E Murat Tuzcu, Samir R Kapadia
1Heart and Vascular Institute, Department of Cardiovascular Medicine, Cleveland Clinic, Cleveland, Ohio.
Objectives:
Our study was aimed at evaluation of three-dimensional (3D)-CT overlay onto the catheterization laboratory fluoroscopy to guide structural cardiac interventions.
Background:
Current imaging for structural cardiac interventions (fluoroscopy, echocardiography) may not provide adequate guidance. The ability to integrate intracardiac 3D-CT imaging data in the cardiac catheterization laboratory may be beneficial, but has not yet been systematically studied.
Methods:
Thirty-two patients undergoing various catheterization laboratory procedures (transcatheter aortic valve replacement, paravalvular leak (PVL) closure, pulmonary vein (PV) stenting, etc.) were prospectively enrolled. The goal was to evaluate the feasibility and benefit of overlaying pre-procedural CT data onto the real-time procedural fluoroscopic image using the Syngo DynaCT Cardiac C-arm CT system (Siemens Healthcare, Forcheim, Germany).
Results:
The overlay was considered most helpful for patients undergoing PVL closure and PV stenting. The additional radiation exposure of the C-arm CT was a fraction of the total procedural dose (3.5% of total skin dose and 9.1% of total DAP).
Conclusions:
Overlay of 3D-CT data onto the real-time procedural fluoroscopy in the cardiac catheterization laboratory is feasible to aide procedural guidance. The overlay was considered most helpful for patients undergoing PVL closure and PV stenting. The additional radiation dose is a small fraction of the total dose. © 2014 Wiley Periodicals, Inc.
More Related Videos
06:59Improved Registration of 3D CT Angiography with X-ray Fluoroscopy for Image Fusion During Transcatheter Aortic Valve Implantation
Published on: June 3, 2018
09:32Time-Resolved, Dynamic Computed Tomography Angiography for Characterization of Aortic Endoleaks and Treatment Guidance via 2D-3D Fusion-Imaging
Published on: December 9, 2021
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Cardiac Catheterization I: Pre-Procedure Overview
Cardiac Catheterization III: Left Heart Catheterization
Imaging Studies for Cardiovascular System IV: CMRI