Similar improvement in gait parameters following direct anterior & posterior approach total hip arthroplasty
Parthiv A Rathod1, Karl F Orishimo2, Ian J Kremenic2
1Center For Joint Preservation and Reconstruction, North Shore LIJ/Lenox Hill Hospital, New York, New York.
Abstract:
We compared gait parameters prior to, at 6 months and 1 year following total hip arthroplasty (THA) performed via direct anterior approach (DAA) and posterior approach (PA) by a single surgeon in 22 patients. A gait analysis system involving reflective markers, infrared cameras and a multicomponent force plate was utilized. Postoperatively, the study cohort demonstrated improvement in flexion/extension range of motion (ROM) (P = 0.001), peak flexion (P = 0.005) and extension (P = 0.002) moments with no differences between groups. Internal/external ROM improved significantly in the DAA group (P = 0.04) with no change in the PA group. THA performed via DAA and PA offers similar improvement in gait parameters with the exception of internal/external ROM which might be related to the release and repair of external rotators during PA THA.