Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Pregabalin Depresses Cerebellar Parallel Fiber-Purkinje Cell Synaptic Transmission by Modulating Glun2a-Containing Nmda Receptors in Mice In Vitro.

International journal of molecular sciences·2026
Same author

Electrical characterization of single tumor cells with high accuracy using a low-cost microfluidic impedance cytometry.

Biosensors & bioelectronics·2026
Same author

[Evaluation of the efficacy and safety of reduced-dose emicizumab in infants with severe hemophilia A: a single-center real-world study].

Zhongguo dang dai er ke za zhi = Chinese journal of contemporary pediatrics·2026
Same author

Oxidized Lipoproteins as Independent Predictors of Major Adverse Cardiovascular Events in Type 2 Diabetes Mellitus with Coronary Heart Disease: A Multicenter Prospective Cohort Study.

Diabetes & metabolism journal·2026
Same author

Forging new insights in forensic microbiome studies: A 2000 to 2024 bibliometric analysis redefining the landscape.

Medicine·2026
Same author

HBsAg Quantification-Based Models for Predicting Hepatocellular Carcinoma Risk in Nucleos(t)ide Analogs-Experienced Patients With Chronic Hepatitis B: The HBsAg-HCC Score.

Alimentary pharmacology & therapeutics·2026
Same journal

EXPRESS: Deterministic Compressed Sensing in Time-Domain Spectroscopy.

Applied spectroscopy·2026
Same journal

EXPRESS: Multi-Parameter Wavelength Characterization of Array Spectrometers Under Near-Limit Sampling Conditions.

Applied spectroscopy·2026
Same journal

EXPRESS: A Validated Reference Database for Twentieth-Century Cd-Based Pigments: Integrated Structural and Compositional Characterization.

Applied spectroscopy·2026
Same journal

EXPRESS: Two-Trace Two-Dimensional (2T2D-COS) in the Analysis of Brain Tissue Sample Preparation Method.

Applied spectroscopy·2026
Same journal

EXPRESS: Simplified Protocol for Analyzing Polarization Properties of Scanning Tunneling Microscope (STM) Light Emission Spectra at an Oblique Angle.

Applied spectroscopy·2026
Same journal

EXPRESS: Monitoring a Polyurethane Synthesis by Fiber-Coupled Attenuated Total Reflection Fourier Transform Infrared Spectroscopy and Multivariate Curve Resolution-Alternating Least Squares.

Applied spectroscopy·2026
See all related articles

Related Experiment Video

Updated: May 4, 2026

Microfluidic Platform with Multiplexed Electronic Detection for Spatial Tracking of Particles
11:54

Microfluidic Platform with Multiplexed Electronic Detection for Spatial Tracking of Particles

Published on: March 13, 2017

8.7K

Microchannel-based surface-enhanced Raman spectroscopy for integrated microfluidic analysis.

Chun-hong Lai1, Li Chen, Gang Chen

  • 1Key Laboratory of Optoelectronic Technology and Systems (Chongqing University), Ministry of Education, Key Disciplines Lab of Novel Micro-nano Devices and System Technology, and School of Optoelectronics Engineering, Chongqing University, Shapingba, Chongqing 400044, China.

Applied Spectroscopy
|January 11, 2014
PubMed
Summary
This summary is machine-generated.

We developed a new microfluidic device for highly sensitive surface-enhanced Raman spectroscopy (SERS) analysis. This approach enables precise biological cell detection with low laser power, offering improved sensitivity for various applications.

More Related Videos

Multimodal Analytical Platform on a Multiplexed Surface Plasmon Resonance Imaging Chip for the Analysis of Extracellular Vesicle Subsets
06:12

Multimodal Analytical Platform on a Multiplexed Surface Plasmon Resonance Imaging Chip for the Analysis of Extracellular Vesicle Subsets

Published on: March 17, 2023

2.2K
Automated System for Single Molecule Fluorescence Measurements of Surface-immobilized Biomolecules
10:57

Automated System for Single Molecule Fluorescence Measurements of Surface-immobilized Biomolecules

Published on: November 2, 2009

14.8K

Related Experiment Videos

Last Updated: May 4, 2026

Microfluidic Platform with Multiplexed Electronic Detection for Spatial Tracking of Particles
11:54

Microfluidic Platform with Multiplexed Electronic Detection for Spatial Tracking of Particles

Published on: March 13, 2017

8.7K
Multimodal Analytical Platform on a Multiplexed Surface Plasmon Resonance Imaging Chip for the Analysis of Extracellular Vesicle Subsets
06:12

Multimodal Analytical Platform on a Multiplexed Surface Plasmon Resonance Imaging Chip for the Analysis of Extracellular Vesicle Subsets

Published on: March 17, 2023

2.2K
Automated System for Single Molecule Fluorescence Measurements of Surface-immobilized Biomolecules
10:57

Automated System for Single Molecule Fluorescence Measurements of Surface-immobilized Biomolecules

Published on: November 2, 2009

14.8K

Area of Science:

  • Analytical Chemistry
  • Microfluidics
  • Spectroscopy

Background:

  • Standard microfabrication techniques are crucial for developing integrated microfluidic systems.
  • Surface-Enhanced Raman Spectroscopy (SERS) offers high sensitivity for molecular detection.
  • Analyzing biological cells requires sensitive and non-destructive sensing methods.

Purpose of the Study:

  • To demonstrate a novel microchannel-based SERS sensing approach for integrated microfluidic analysis.
  • To achieve high-sensitivity SERS detection with low excitation optical power.
  • To enable sensitive analysis of biological cells using microfluidic devices.

Main Methods:

  • Development of a microchannel using standard microfabrication technology.
  • Integration of SERS sensing within the microfluidic channel (100 × 70 μm cross-section).
  • Measurement of rhodamine 6G detection limits at low excitation power (132 W/cm²).

Main Results:

  • Achieved a detection limit below 10 nM for rhodamine 6G.
  • Demonstrated high-sensitivity SERS sensing with low excitation optical power.
  • Confirmed minimal sample heating effects due to low power intensity.

Conclusions:

  • The developed microchannel-based SERS approach enables sensitive biological cell analysis.
  • The system offers high sensitivity with low optical power, avoiding sample damage.
  • Significant potential exists for further enhancing the sensitivity of this SERS detection method.