Related Experiment Video
Updated: May 4, 2026

Selecting Multiple Biomarker Subsets with Similarly Effective Binary Classification Performances
Published on: October 11, 2018
Experience with BioMatrix BES and other DES in all-comers setting: a retrospective overview
B K Goyal1, B C Kalmath2, Ramesh Kawar2
1Interventional Cardiologist, Bombay Hospital of Medical Sciences, Mumbai 400020, India; Director, Medical Education and Research, Bombay Hospital, India.
Abstract:
New generation DES are effectively used in all spectrum of coronary artery diseases (CAD) and are replacing earlier DES and BMS. Biolimus A9™-eluting stent is a new generation DES containing the anti-proliferative drug biolimus A9™ incorporating a biodegradable abluminal coating that leaves a polymer-free stent after drug release enhancing strut coverage while preventing neointimal hyperplasia. A retrospective data analysis was done in patients treated with DES, with a major share of Biolimus A9™ (BA9™) drug-eluting stents (DES) at Bombay Hospital, Mumbai. A total of 158 patients with 219 lesions were treated with DES, comprising Biolimus A9-eluting stent and others and the major adverse cardiac events (MACE) rate and stent thrombosis (ST) at 1, 6, 12 months and 24 months were analyzed. Mace rate was 3.16% for average follow-up of 19 months. There were 3 cases of ST (2 of acute and 1 of subacute onset) and one non-cardiac death reported during this time. This retrospective data demonstrates good one- and two-year clinical safety and efficacy of DES, especially of BioMatrix stents in real world setting.
Related Concept Videos
Bioequivalence Experimental Study Designs: Repeated Measures, Cross-Over, Carry-Over, and Latin Square Designs
Types of Biopharmaceutical Studies: Controlled and Non-Controlled Approaches
Non-controlled studies, commonly employed for initial exploration, lack a control group, rendering them susceptible to biases and external influences. In contrast,...
Bioequivalence studies: Biowaivers
Bioequivalence Experimental Study Designs: Completely Randomized and Randomized Block Designs
Bioequivalence: Overview